RESEARCH / DISCOVERY
← Back to the library

Self-supervised identification and elimination of harmful datasets in distributed machine learning for medical image analysis.

Self-supervised identification and elimination of harmful datasets in distributed machine learning for medical image analysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Calgary, CA · Author affiliation

Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada. raissa.souzadeandrad@ucalgary.ca.
Location evidence

Edmonton, CA · Author affiliation

Neuroscience and Mental Health Institute and Department of Medicine (Neurology), University of Alberta, Edmonton, AB, Canada.
Location evidence

Montréal, CA · Author affiliation

Department of Radiology, Radio-oncology and Nuclear Medicine, Université de Montréal, Montréal, QC, Canada.
Location evidence

Exeter, GB · Author affiliation

Clinical and Biomedical Sciences, Faculty of Health and Life Sciences, University of Exeter, Exeter, UK.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Distributed learning enables collaborative machine learning model training without requiring cross-institutional data sharing, thereby addressing privacy concerns. However, local quality control variability can negatively impact model performance while systematic human visual inspection is time-consuming and may violate the goal of keeping data inaccessible outside acquisition centers. This work proposes a novel self-supervised method to identify and eliminate harmful data during distributed learning model training fully-automatically. Harmful data is defined as samples that, when included in training, increase misdiagnosis rates. The method was tested using neuroimaging data from 83 centers for Parkinson's disease classification with simulated inclusion of a few harmful data samples. The proposed method reliably identified harmful images, with centers providing only harmful datasets being easier to identify than single harmful images within otherwise good datasets. While only evaluated using neuroimaging data, the presented method is application-agnostic and presents a step towards automated quality control in distributed learning.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE