RESEARCH / DISCOVERY
← Back to the library

Detecting freezing of gait: A comprehensive toolkit for enhanced Parkinson's assessment.

Detecting freezing of gait: A comprehensive toolkit for enhanced Parkinson's assessment.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Bangkok, TH · Author affiliation

Chulalongkorn Centre of Excellence for Parkinson's Disease & Related Disorders, Department of Medicine, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, 10330, Thailand.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Detecting Freezing of Gait (FOG) poses challenges, with the subjective 6-item FOG Questionnaire relying solely on patient perception. We aim to create a holistic FOG Detection Toolkit combining subjective and objective elements (descriptions, images, and videos) to improve FOG detection precision. METHODS: Development of the FOG Detection Toolkit involved a detailed cover sheet on FOG and its triggers, along with video exemplars and a 4-item FOG-specific self-assessment questionnaire, all rigorously validated. The toolkit was administered to 100 eligible consecutive Parkinson's disease (PD) patients at a PD referral clinic in a major public university hospital in Thailand. The FOG Detection Toolkit results are based on the total score from a 4-item FOG-specific self-assessment questionnaire (range: 0-16). Freezers were identified by scores ≥6. RESULTS: The cover sheet, images, and videos displayed robust content validity and inter-rater reliability. The 4-item questionnaire exhibited high sensitivity (98 %) and specificity (100 %), with a substantial Area Under the Curve (AUC) of 0.990 and satisfactory construct validity (r = 0.68; p = 0.01). Users reported positive pragmatic (1.75) and hedonic (1.34) experiences. Patients with FOG scored significantly higher on the Toolkit and demonstrated distinct gait parameters (p < 0.001). CONCLUSION: The FOG Detection Toolkit showcases strong diagnostic performance, adequate construct validity, and positive user experience, facilitating accurate FOG detection. Its utility extends outside clinical environments, promising broader applicability for FOG management.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE