PADS-Net: GAN-based radiomics using multi-task network of denoising and segmentation for ultrasonic diagnosis of Parkinson disease.
PADS-Net: GAN-based radiomics using multi-task network of denoising and segmentation for ultrasonic diagnosis of Parkinson disease.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Shanghai, CN · Author affiliation
The SMART (Smart Medicine and AI-based Radiology Technology) Lab, Shanghai Institute for Advanced Communication and Data Science, Shanghai University, Shanghai, China; Key Laboratory of Specialty Fiber Optics and Optical Access Networks, School of Communication and Information Engineering, Shanghai University, Shanghai, China.Location evidence
Huashan, CN · Author affiliation
Department of Ultrasound, National Clinical Research Center for Aging and Medicine, Huashan Hospital, Fudan University, Shanghai, China.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Parkinson disease (PD) is a prevalent neurodegenerative disorder, and its accurate diagnosis is crucial for timely intervention. We propose the PArkinson disease Denoising and Segmentation Network (PADS-Net), to simultaneously denoise and segment transcranial ultrasound images of midbrain for accurate PD diagnosis. The PADS-Net is built upon generative adversarial networks and incorporates a multi-task deep learning framework aimed at optimizing the tasks of denoising and segmentation for ultrasound images. A composite loss function including the mean absolute error, the mean squared error and the Dice loss, is adopted in the PADS-Net to effectively capture image details. The PADS-Net also integrates radiomics techniques for PD diagnosis by exploiting high-throughput features from ultrasound images. A four-branch ensemble diagnostic model is designed by utilizing two "wings" of the butterfly-shaped midbrain regions on both ipsilateral and contralateral images to enhance the accuracy of PD diagnosis. Experimental results demonstrate that the PADS-Net not only reduced speckle noise, achieving the edge-to-noise ratio of 16.90, but also attained a Dice coefficient of 0.91 for midbrain segmentation. The PADS-Net finally achieved an area under the receiver operating characteristic curve as high as 0.87 for diagnosis of PD. Our PADS-Net excels in transcranial ultrasound image denoising and segmentation and offers a potential clinical solution to accurate PD assessment.