RESEARCH / DISCOVERY
← Back to the library

High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson's Disease Model Mice and Humans.

High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson's Disease Model Mice and Humans.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Shangqiu, CN · Author affiliation

Henan Key Laboratory of Biomolecular Recognition and Sensing, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu 476000, China.
Location evidence

Zhengzhou, CN · Author affiliation

College of Chemistry, Zhengzhou University, Zhengzhou 450001, China.
Location evidence

Xinxiang, CN · Author affiliation

School of Chemistry & Materials Engineering, Xinxiang University, Xinxiang 453000, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by the loss of dopaminergic neurons and the accumulation of alpha-synuclein. Glutathione (GSH), a key antioxidant, is significantly depleted in PD patients. This study presents a dual-mode detection strategy for selectively determining GSH using a single probe. A series of "turn-on" electrochemical and fluorescent probes were developed, with resorufin (Re) serving as the reporting unit and featuring specific GSH recognition sites. Among these, the 7-(3,5-dinitrophenoxy)-3H-phenoxazin-3-one (Re-DNP) probe was selected for its high selectivity as both a fluorescent and electrochemical probe. Its response to GSH was superior in comparison to that observed for hydrogen sulfide (H2S) and cysteine (Cys). For electrochemical detection using screen-printed carbon electrode (SPCE)/carbon nanotube (CNT) modified electrodes, the detection limit for GSH was 5 μM, with a linear range of 25-500 μM. In fluorescence detection, the probe produced a 78-fold increase in emission at 630 nm in the presence of GSH, with a strong linear correlation between fluorescence intensity and GSH concentration in the range of 10-700 μM, and a detection limit of 2 μM. When applied to real clinical serum samples, the probe demonstrated significantly lower GSH levels in both PD mice and human patients compared to healthy controls. This dual-mode detection method provides a sensitive and accurate tool for GSH detection, with potential applications in understanding GSH's role in PD and related neurodegenerative diseases.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE