RESEARCH / DISCOVERY
← Back to the library

Oxidative Stress Monitoring Platform: A Longitudinal In vitro Multinuclear (1H/19F) MR Spectroscopic Study.

Oxidative Stress Monitoring Platform: A Longitudinal In vitro Multinuclear (1H/19F) MR Spectroscopic Study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

IN · Author affiliation · country only

Neuroimaging and Neurospectroscopy (NINS) Laboratory, National Brain Research Centre, Gurgaon, India. mandalpk@pitt.edu.
Location evidence

Pittsburgh, US · Author affiliation

Department of Neurosurgery, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA. mandalpk@pitt.edu.
Location evidence

Melbourne, AU · Author affiliation

Florey Institute of Neuroscience and Mental Health, Melbourne School of Medicine Campus, Melbourne, VIC, Australia. mandalpk@pitt.edu.
Location evidence

Chandigarh, IN · Author affiliation

Department of Forensic Science, Chandigarh University, Mohali, Punjab, India.
Location evidence

Mohali, IN · Author affiliation

Department of Forensic Science, Chandigarh University, Mohali, Punjab, India.
Location evidence

Messina, IT · Author affiliation

Department of Human Pathology of the Adult and Evolutive Age "Gaetano Barresi", Section of Anesthesiology, University of Messina, Messina, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Glutathione (GSH) is a master antioxidant that counters oxidative stress. Clinical studies have confirmed significant depletion of GSH in the hippocampus and the substantia nigra as an early diagnostic biomarker for Alzheimer's disease (AD) and Parkinson disease (PD), respectively. External agents like anesthetics (inhaled and intravenous) have a different impact on GSH. There is significant depletion of the serum GSH peroxidase level after surgery with isoflurane anesthesia that is not found in patients administered intravenous propofol. The objective of this study is to evaluate the GSH level associated with isoflurane in vitro phantom model using non-invasive magnetic resonance (MR) spectroscopy and to detect residual isoflurane in a solution. MRS data was generated utilizing a 3T MR scanner (Prisma, Siemens) equipped with a 64-channel 1H head coil and dual tune (19F/1H) head coil. The GSH data acquisition was performed using the MEGA-PRESS pulse sequence using experimental parameters: ON = 4.40 ppm, OFF = 5.00 ppm, TE = 120 ms, TR = 2500 ms, voxel size = 25 × 25 × 25 mm and average = 32. Isoflurane was detected using 19F MRS studies using 19F/1H head coil. GSH data was processed using KALPANA package and 19F data was processed using Siemens package. The GSH peak area (without isoflurane) in a phosphate-buffered solution (PBS) solution (control) showed a slow decline over time due to natural oxidation of GSH to dimeric glutathione (GSSG). On the contrary, the GSH peak area in similar model is reduced significantly (p = 0.016) due to isoflurane induced oxidation of GSH to GSSG compared to control. We also report a concise general method for data generation and processing of 1H MRS data for GSH as well as 19F monitoring platform using 19F MR spectroscopy. This is the first report wherein both 1H and 19F spectroscopy are applied to generate MRS data along with a unique data processing method. This method is highly sensitive and specifically detects GSH without ambiguity as well as isoflurane due to the unique chemical shift patterns of CF3 and CHF2 moieties. This non-invasive MRS approach is developed to monitor GSH-isoflurane interaction leading to oxidative stress and this approach can be extended for other inhaled anesthetics. This methodology using non-invasive 19F MR spectroscopy needs further development for future clinical studies.