RESEARCH / DISCOVERY
← Back to the library

Wearable Surface Electromyography System to Predict Freeze of Gait in Parkinson's Disease Patients.

Wearable Surface Electromyography System to Predict Freeze of Gait in Parkinson's Disease Patients.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

East Lansing, US · Author affiliation

Precision Health Program, Michigan State University, East Lansing, MI 48824, USA.
Location evidence

Hopkins, US · Author affiliation

Applied Physics Laboratory, Johns Hopkins University, Laurel, MD 20723, USA.
Location evidence

US · Author affiliation · country only

Ohio Health Riverside Methodist Hospital, Columbus, OH 43214, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Freezing of gait (FOG) is a disabling yet poorly understood paroxysmal gait disorder affecting the vast majority of patients with Parkinson's disease (PD) as they reach advanced stages of the disorder. Falling is one of the most disabling consequences of a FOG episode; it often results in injury and a future fear of falling, leading to diminished social engagement, a reduction in general fitness, loss of independence, and degradation of overall quality of life. Currently, there is no robust or reliable treatment against FOG in PD. In the absence of reliable and effective treatment for Parkinson's disease, alleviating the consequences of FOG represents an unmet clinical need, with the first step being reliable FOG prediction. Current methods for FOG prediction and prevention cannot provide real-time readouts and are not sensitive enough to detect changes in walking patterns or balance. To fill this gap, we developed an sEMG system consisting of a soft, wearable garment (pair of shorts and two calf sleeves) embedded with screen-printed electrodes and stretchable traces capable of picking up and recording the electromyography activities from lower limb muscles. Here, we report on the testing of these garments in healthy individuals and in patients with PD FOG. The preliminary testing produced an initial time-to-onset commencement that persisted > 3 s across all patients, resulting in a nearly 3-fold drop in sEMG activity. We believe that these initial studies serve as a solid foundation for further development of smart digital textiles with integrated bio and chemical sensors that will provide AI-enabled, medically oriented data.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE