RESEARCH / DISCOVERY
← Back to the library

Test-retest and inter-rater reliability and construct validity of the 2-minute step test in individuals with Parkinson's disease.

Test-retest and inter-rater reliability and construct validity of the 2-minute step test in individuals with Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

São Luís, BR · Author affiliation

Postgraduate Program in Physical Education, Universidade Federal do Maranhão, São Luís, Brazil; Sarah Network of Rehabilitation Hospitals, São Luís, Brazil. Electronic address: marinagenari@gmail.com.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: To evaluate the test-retest and inter-rater reliability and construct validity of the 2-min step test (2MST) in individuals with Parkinson's disease (PD). METHODS: Two previously trained examiners applied the 2MST in two moments. Clinical measurements of PD were obtained using the following instruments: Berg Balance Scale (BBS), Unified Parkinson's Disease Rating Scale (UPDRS), modified Hoehn and Yahr Scale (H&Y), gait speed and cadence, 5-time Sit-to-Stand Test (5TSST) and Timed Up and Go (TUG). For reliability, the intraclass correlation coefficient (ICC), standard error of measurement (SEM) and minimal detectable change (MDC) were calculated. For construct validity, Pearson's and Spearman's correlation coefficient were used. The agreement between the measurement in person and via recorded video was assessed by means of Bland-Altman plots. RESULTS: The 2MST showed adequate test-retest reliability (ICC = 0.80, SEM = 10.59, MDC = 29.35) and excellent inter-rater reliability (ICC = 0.93, SEM = 4.49, MDC = 12.46). There was acceptable agreement between assessments made with in person and via video. A correlation magnitude above 0.50 was found between 2MST and gait speed, and a correlation magnitude between 0.30 and 0.50 with BBS, gait cadence, UPDRS and TUG. CONCLUSION: The 2MST presents adequate test-retest and inter-rater reliability and a valid construct to evaluate the aerobic endurance of individuals with PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE