RESEARCH / DISCOVERY
← Back to the library

Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.

Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Bern, CH · Author affiliation

Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.
Location evidence

Huashan, CN · Author affiliation

Department of Nuclear Medicine / PET Center, Huashan Hospital, Fudan University, Shanghai, 200235, China.
Location evidence

Shanghai, CN · Author affiliation

Department of Nuclear Medicine / PET Center, Huashan Hospital, Fudan University, Shanghai, 200235, China.
Location evidence

Vienna, AT · Author affiliation

Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.
Location evidence

Munich, DE · Author affiliation

TUM School of Medicine, Technical University of Munich, Munich, Germany.
Location evidence

Knoxville, US · Author affiliation

Siemens Medical Solutions USA, Inc., Molecular Imaging, Knoxville, TN, USA.
Location evidence

Hamburg, DE · Author affiliation

Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

PURPOSE: Dopamine transporter imaging is routinely used in Parkinson's disease (PD) and atypical parkinsonian syndromes (APS) diagnosis. While [11C]CFT PET is prevalent in Asia with a large APS database, Europe relies on [123I]FP-CIT SPECT with limited APS data. Our aim was to develop a deep learning-based method to convert [11C]CFT PET images to [123I]FP-CIT SPECT images, facilitating multicenter studies and overcoming data scarcity to promote Artificial Intelligence (AI) advancements. METHODS: A CycleGAN was trained on [11C]CFT PET (n = 602, 72%PD) and [123I]FP-CIT SPECT (n = 1152, 85%PD) images from PD and non-parkinsonian control (NC) subjects. The model generated synthetic SPECT images from a real PET test set (n = 67, 75%PD). Synthetic images were quantitatively and visually evaluated. RESULTS: Fréchet Inception Distance indicated higher similarity between synthetic and real SPECT than between synthetic SPECT and real PET. A deep learning classification model trained on synthetic SPECT achieved sensitivity of 97.2% and specificity of 90.0% on real SPECT images. Striatal specific binding ratios of synthetic SPECT were not significantly different from real SPECT. The striatal left-right differences and putamen binding ratio were significantly different only in the PD cohort. Real PET and real SPECT had higher contrast-to-noise ratio compared to synthetic SPECT. Visual grading analysis scores showed no significant differences between real and synthetic SPECT, although reduced diagnostic performance on synthetic images was observed. CONCLUSION: CycleGAN generated synthetic SPECT images visually indistinguishable from real ones and retained disease-specific information, demonstrating the feasibility of translating [11C]CFT PET to [123I]FP-CIT SPECT. This cross-modality synthesis could enhance further AI classification accuracy, supporting the diagnosis of PD and APS.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE