Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.
Dopaminergic PET to SPECT domain adaptation: a cycle GAN translation approach.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Bern, CH · Author affiliation
Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Freiburgstrasse 18, Bern, 3010, Switzerland.Location evidence
Huashan, CN · Author affiliation
Department of Nuclear Medicine / PET Center, Huashan Hospital, Fudan University, Shanghai, 200235, China.Location evidence
Shanghai, CN · Author affiliation
Department of Nuclear Medicine / PET Center, Huashan Hospital, Fudan University, Shanghai, 200235, China.Location evidence
Vienna, AT · Author affiliation
Department of Biomedical Imaging and Image-Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.Location evidence
Munich, DE · Author affiliation
TUM School of Medicine, Technical University of Munich, Munich, Germany.Location evidence
Knoxville, US · Author affiliation
Siemens Medical Solutions USA, Inc., Molecular Imaging, Knoxville, TN, USA.Location evidence
Hamburg, DE · Author affiliation
Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
PURPOSE: Dopamine transporter imaging is routinely used in Parkinson's disease (PD) and atypical parkinsonian syndromes (APS) diagnosis. While [11C]CFT PET is prevalent in Asia with a large APS database, Europe relies on [123I]FP-CIT SPECT with limited APS data. Our aim was to develop a deep learning-based method to convert [11C]CFT PET images to [123I]FP-CIT SPECT images, facilitating multicenter studies and overcoming data scarcity to promote Artificial Intelligence (AI) advancements. METHODS: A CycleGAN was trained on [11C]CFT PET (n = 602, 72%PD) and [123I]FP-CIT SPECT (n = 1152, 85%PD) images from PD and non-parkinsonian control (NC) subjects. The model generated synthetic SPECT images from a real PET test set (n = 67, 75%PD). Synthetic images were quantitatively and visually evaluated. RESULTS: Fréchet Inception Distance indicated higher similarity between synthetic and real SPECT than between synthetic SPECT and real PET. A deep learning classification model trained on synthetic SPECT achieved sensitivity of 97.2% and specificity of 90.0% on real SPECT images. Striatal specific binding ratios of synthetic SPECT were not significantly different from real SPECT. The striatal left-right differences and putamen binding ratio were significantly different only in the PD cohort. Real PET and real SPECT had higher contrast-to-noise ratio compared to synthetic SPECT. Visual grading analysis scores showed no significant differences between real and synthetic SPECT, although reduced diagnostic performance on synthetic images was observed. CONCLUSION: CycleGAN generated synthetic SPECT images visually indistinguishable from real ones and retained disease-specific information, demonstrating the feasibility of translating [11C]CFT PET to [123I]FP-CIT SPECT. This cross-modality synthesis could enhance further AI classification accuracy, supporting the diagnosis of PD and APS.