RESEARCH / DISCOVERY
← Back to the library

Three hertz orthostatic tremor as "red flag sign" candidate for multiple system atrophy.

Three hertz orthostatic tremor as "red flag sign" candidate for multiple system atrophy.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Guangzhou, CN · Author affiliation

Department of Neurology, The Sixth Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

AIM: This study investigates the potential of 3-Hz orthostatic tremor (OT) as a diagnostic red-flag sign for differentiating multiple system atrophy (MSA) from Parkinson's disease (PD). PATIENTS AND METHODS: A total of 615 PD patients and 234 MSA patients (120 MSA-P and 114 MSA-C) participated. OT at ~ 3 Hz and other frequencies was identified through rhythmic postural sway on the stabilogram map and confirmed by fast Fourier transform (FFT) analysis. Extensive assessment of OT occurrence, preferential stance conditions, sway direction, frequency spectrum, and intensity was performed and compared between the two diseases. RESULTS: Significant differences in OT features were observed. In PD, 104 patients (16.9%) exhibited tremors, mainly on a firm platform (79.8%), and preferentially in the medial-lateral direction (59.6%). About 40% of PD-related OT showed double peaks in the FFT map, with a frequency spectrum from 3.3 to 12.4 Hz. MSA tremors were observed in 133 patients (56.8%, including 46 MSA-P and 87 MSA-C patients), occurring after proprioceptive sensory input deprivation (94.7%). OT in MSA occurred exclusively in the anterior-posterior direction (100%), with no sub- or ultra-harmonics in the FFT map. Binominal logistic regression analyses demonstrated that frequency and stance conditions independently contributed to differentiating PD- and MSA-related OT. The 3-Hz tremor exhibited a sensitivity of 0.568, perfect specificity (1), an approximate negative predictive value of 0.8592, and a positive predictive value of 1 for MSA identification. CONCLUSIONS: This study establishes the 3-Hz orthostatic tremor as a promising red flag sign for MSA identification.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE