RESEARCH / DISCOVERY
← Back to the library

Screen-printed, biocompatible and ultrasensitive sensor for real-time reactive oxygen species detection in human sweat.

Screen-printed, biocompatible and ultrasensitive sensor for real-time reactive oxygen species detection in human sweat.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Chengdu, CN · Author affiliation

Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital, Chengdu, 610072, China.
Location evidence

US · Author affiliation · country only

Department of Materials Science and Engineering, University of Wisconsin-Madison, Madison, WI, 53706, United States.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Excessive or burst generation of reactive oxygen species (ROS) can induce oxidative stress, precipitating a range of critical illnesses, including cancers, Parkinson's disease and Ischemia-reperfusion injury. Conventional biological assays for ROS, involving discrete steps of capturing, labelling, and spectrometric detection, are complex and time-intensive. Moreover, their accuracy is substantially compromised by the short lifespan (microseconds to milliseconds) of ROS. Consequently, there is a pressing need for a rapid and efficient method that enables real-time detection. In this study, we have developed a printable, flexible ROS sensor based on a robust nanoenzyme composite by direct deposition of the paste onto a flexible polyethylene terephthalate (PET) substrate. This device demonstrated the fast and real-time responses to the hydrogen peroxide (mimetic agent) in the laboratory and to total ROS in sweat of an individual, exhibiting an outstanding current response to hydrogen peroxide across a broad concentration range of 0.01-10 mM, with a limit of detection (LOD) of 1.85 μM. The device's sensitivity to hydrogen peroxide (136.59 μA mM-1 cm-2), was found to be 1.5 to 10 times higher than that of sensors previously reported. Moreover, the IFRS device successfully identified instantaneous ROS levels in the sweat of adult males in vitro, with amperometric response increased 8 times after half an hour strenuous exercise, thereby exhibiting excellent selectivity, remarkable stability, and confirmed high biosafety. Overall, the IFRS provides a viable and practical solution for simple, expedited, and real-time ROS detection in the near future.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE