RESEARCH / DISCOVERY
← Back to the library

Accuracy of 18F-FDG PET Imaging in Differentiating Parkinson's Disease from Atypical Parkinsonian Syndromes: A Systematic Review and Meta-Analysis.

Accuracy of 18F-FDG PET Imaging in Differentiating Parkinson's Disease from Atypical Parkinsonian Syndromes: A Systematic Review and Meta-Analysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Zhengzhou, CN · Author affiliation

Department of Neurosurgery, The Fifth Affiliated Hospital of Zhengzhou University, Zhengzhou 450052, Henan, China.
Location evidence

Beijing, CN · Author affiliation

Department of Cardiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing 100000, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

RATIONALE AND OBJECTIVE: To quantitatively assess the accuracy of 18F-FDG PET in differentiating Parkinson's Disease (PD) from Atypical Parkinsonian Syndromes (APSs). METHODS: PubMed, Embase, and Web of Science databases were searched to identify studies published from the inception of the databases up to June 2024 that used 18F-FDG PET imaging for the differential diagnosis of PD and APSs. The risk of bias in the included studies was assessed using the QUADAS-2 or QUADAS-AI tool. Bivariate random-effects models were used to calculate the pooled sensitivity, specificity, and the area under the curves (AUC) of summary receiver operating characteristic (SROC). RESULTS: 24 studies met the inclusion criteria, involving a total of 1508 PD patients and 1370 APSs patients. 12 studies relied on visual interpretation by radiologists, of which the pooled sensitivity, specificity, and SROC-AUC for direct visual interpretation in diagnosing PD were 96% (95%CI: 91%, 98%), 90% (95%CI: 83%, 95%), and 0.98 (95%CI: 0.96, 0.99), respectively; the pooled sensitivity, specificity, and SROC-AUC for visual interpretation supported by univariate algorithms in diagnosing PD were 93% (95%CI: 90%, 95%), 90% (95%CI: 85%, 94%), and 0.96 (95%CI: 0.94, 0.97), respectively. 12 studies relied on artificial intelligence (AI) to analyze 18F-FDG PET imaging data. The pooled sensitivity, specificity, and SROC-AUC of machine learning (ML) for diagnosing PD were 87% (95%CI: 82%, 91%), 91% (95%CI: 86%, 94%), and 0.95 (95%CI: 0.93, 0.96), respectively. The pooled sensitivity, specificity, and SROC-AUC of deep learning (DL) for diagnosing PD were 97% (95%CI: 95%, 98%), 95% (95%CI: 89%, 98%), and 0.98 (95%CI: 0.96, 0.99), respectively. CONCLUSION: 18F-FDG PET has a high accuracy in differentiating PD from APS, among which AI-assisted automatic classification performs well, with a diagnostic accuracy comparable to that of radiologists, and is expected to become an important auxiliary means of clinical diagnosis in the future.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE