RESEARCH / DISCOVERY
← Back to the library

Highly efficient electrocatalytic oxidation of levodopa as a Parkinson therapeutic drug based on modified screen-printed electrode.

Highly efficient electrocatalytic oxidation of levodopa as a Parkinson therapeutic drug based on modified screen-printed electrode.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

CN · Author affiliation · country only

Three Gorges University, College of Basie Medical Scienees, 443002, China.
Location evidence

Karbala, IQ · Author affiliation

Al-Zahraa Center for Medical and Pharmaceutical Research Sciences (ZCMRS), Al-Zahraa University for Women, Karbala, 56001, Iraq.
Location evidence

IQ · Author affiliation · country only

Anesthesia Techniques Department, College of Health and Medical Techniques, Al-Mustaqbal University, 51001, Babylon, Iraq.
Location evidence

Baghdad, IQ · Author affiliation

Department of Medical Engineering, Al-Esraa University College, Baghdad, Iraq.
Location evidence

Najaf, IQ · Author affiliation

Department of Medical Laboratory Techniques, Altoosi University College, Najaf, Iraq.
Location evidence

Abha, SA · Author affiliation

Department of Clinical Laboratory Sciences, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia.
Location evidence

Al Diwaniyah, IQ · Author affiliation

College of technical engineering, the Islamic University of Al Diwaniyah, Iraq.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The current study presents the creation of a straightforward and sensitive sensor based on ZnO/Co3O4 nanocomposite modified screen-printed electrode (ZnO/Co3O4NC/SPE) for levodopa determination. At ZnO/Co3O4NC/SPE, an oxidative peak for levodopa solution in pH 6.0 phosphate buffer solution (PBS) were seen that were both more resolved and more enhanced. Levodopa was measured using differential pulse voltammetry (DPV), which showed an excellent linear range (0.001-800.0 μM) and detection limit (0.81 nM). The presence of interference did not affect the electrochemical response of levodopa at ZnO/Co3O4NC/SPE, demonstrating high selectivity. Levodopa in a real samples have been successfully detected using the manufactured sensor.