RESEARCH / DISCOVERY
← Back to the library

Simultaneous time-frequency analysis of gait signals of both legs in classifying neurodegenerative diseases.

Simultaneous time-frequency analysis of gait signals of both legs in classifying neurodegenerative diseases.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Mashhad, IR · Author affiliation

Department of Biomedical Engineering, Mashhad Branch, Islamic Azad University, Mashhad, Iran.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Neurodegenerative diseases (NDDs) pose significant challenges due to their debilitating nature and limited therapeutic options. Accurate and timely diagnosis is crucial for optimizing patient care and treatment strategies. Gait analysis, utilizing wearable sensors, has shown promise in assessing motor abnormalities associated with NDDs. RESEARCH QUESTION: Research Question 1 To what extent can analyzing the interaction of both limbs in the time-frequency domain serve as a suitable methodology for accurately classifying NDDs? Research Question 2 How effective is the utilization of color-coded images, in conjunction with deep transfer learning models, for the classification of NDDs? METHODS: GaitNDD database was used, comprising recordings from patients with Huntington's disease, amyotrophic lateral sclerosis, Parkinson's disease, and healthy controls. The gait signals underwent signal preparation, wavelet coherence analysis, and principal component analysis for feature enhancement. Deep transfer learning models (AlexNet, GoogLeNet, SqueezeNet) were employed for classification. Performance metrics, including accuracy, sensitivity, specificity, precision, and F1 score, were evaluated using 5-fold cross-validation. RESULTS: The classification performance of the models varied depending on the time window used. For 5-second gait signal segments, AlexNet achieved an accuracy of 95.91 %, while GoogLeNet and SqueezeNet achieved accuracies of 96.49 % and 92.73 %, respectively. For 10-second segments, AlexNet outperformed other models with an accuracy of 99.20 %, while GoogLeNet and SqueezeNet achieved accuracies of 96.75 % and 95.00 %, respectively. Statistical tests confirmed the significance of the extracted features, indicating their discriminative power for classification. SIGNIFICANCE: The proposed method demonstrated superior performance compared to previous studies, offering a non-invasive and cost-effective approach for the automated diagnosis of NDDs. By analyzing the interaction between both legs during walking using wavelet coherence, and utilizing deep transfer learning models, accurate classification of NDDs was achieved.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE