Efficient application of Pyrosin B for nano-gram level assay of antiparkinsonian medication, rasagiline: Evaluation of tablets and content uniformity.
Efficient application of Pyrosin B for nano-gram level assay of antiparkinsonian medication, rasagiline: Evaluation of tablets and content uniformity.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Assiut, EG · Author affiliation
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Al-Azhar University, Assiut Branch, Assiut, Egypt.Location evidence
Riyadh, SA · Author affiliation
Department of Pharmaceutics, College of Pharmacy, King Saud University, Riyadh, Saudi Arabia.Location evidence
Shaqra, SA · Author affiliation
Department of Pharmaceutical Chemistry, College of Pharmacy, Shaqra University, Shaqra, Saudi Arabia.Location evidence
EG · Author affiliation · country only
Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, South Valley University, Qena, Egypt.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Rasagiline (RAS) is a medication for Parkinson's disease that increases dopamine levels in the brain by inhibiting monoamine oxidase, helping to alleviate symptoms. The proposed study aims to develop an efficient, feasible, and sensitive method for RAS assay, utilizing Pyrosin B dye, a convenient fluorescent ligand. Combining the RAS analyte with Pyrosin B ligand in a mildly acidic buffered solution rapidly quenches the native fluorescence of the ligand. This quenching results from the formation of a specific ion-dipole association complex between the lone pair-bearing atoms of the ligand and the protonated amine moiety of RAS, highlighting their interactive chemistry under these conditions. The degree of this interaction demonstrated superior sensitivity compared with reported alternatives, exhibiting a linear range of 50.0 to 1000.0 ng/mL. The method is characterized by a limit of detection (LOD) of 16.0 ng/mL and a limit of quantification (LOQ) of 48.0 ng/mL. By optimizing the RAS-Pyrosin B system, the variable parameters were finely tuned, ensuring the assay method's reliability. The method's accuracy, precision, selectivity, and robustness were validated according to International Council for Harmonization (ICH) guidelines, enabling precise and efficient analysis of RAS in the nanogram range. This method streamlines the analysis procedure and reduces environmental impact, making it a promising approach for the quality control of ParkintreatR tablets (1 mg) and other analytical applications.