RESEARCH / DISCOVERY
← Back to the library

Intraoperative DBS targeting of the globus pallidus internus by using motor evoked potentials.

Intraoperative DBS targeting of the globus pallidus internus by using motor evoked potentials.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Düsseldorf, DE · Author affiliation

Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany; Max Planck Institute for Empirical Aesthetics, Frankfurt am Main, Germany.
Location evidence

Frankfurt am Main, DE · Author affiliation

Institute of Clinical Neuroscience and Medical Psychology, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany; Max Planck Institute for Empirical Aesthetics, Frankfurt am Main, Germany.
Location evidence

Krefeld, DE · Author affiliation

Department of Orthopaedics, Trauma Surgery and Hand Unit, Helios Klinikum Krefeld, Krefeld, Germany; Department of Functional Neurosurgery and Stereotaxy, Medical Faculty, Heinrich Heine University, Düsseldorf, Germany; Faculty of Medicine, Heinrich Heine University, Düsseldorf, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVES: Target localization for deep brain stimulation (DBS) is a crucial step that influences the clinical benefit of the DBS procedure together with the reduction of side effects. In this work, we address the feasibility of DBS target localization in the globus pallidus internus (GPi) aided by intraoperative motor evoked potentials (MEP) with emphasis on the reduction of capsular side effects. MATERIAL AND METHODS: Micro-macroelectrode recordings were performed intraoperatively on 20 patients that underwent DBS treatment of the GPi (GPi-DBS). MEP were elicited intraoperatively by microelectrode stimulation during stereotactic DBS surgery. We studied the relationship between MEP thresholds and the internal capsule (IC) proximity. RESULTS: We found a significant correlation between intraoperative MEP thresholds and IC proximity. CONCLUSIONS: We provide further evidence of the role of MEPs for DBS target localization in the GPi, which extends and confirms the usefulness of MEPs as previously reported by DBS target localization studies dealing with the subthalamic and thalamic nuclei. Our approach is advantageous in that it provides criteria to determine the DBS target without the need to rely on a patient's response while avoiding capsular effects.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE