RESEARCH / DISCOVERY
← Back to the library

Differential diagnosis value of sympathetic skin response and cutaneous silent period on early-stage multiple system atrophy and Parkinson disease.

Differential diagnosis value of sympathetic skin response and cutaneous silent period on early-stage multiple system atrophy and Parkinson disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Guangzhou, CN · Author affiliation

Department of Neurology, Guangdong Neuroscience Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China; Guangzhou Key Laboratory of Diagnosis and Treatment for Neurodegenerative Diseases, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

PURPOSE: Early differentiation between Parkinson's disease (PD) and Multiple system atrophy (MSA), particularly the parkinsonian subtypes (MSA-P), is challenging due to similar clinical symptoms. We aimed to evaluate Sympathetic skin response (SSR) and Cutaneous silent period (CSP) parameters in patients with MSA-P and PD to identify possible biomarkers that could distinguish the two groups of patients in early stage. METHODS: 22 individuals with early-stage MSA-P, 29 with early-stage PD, and 28 healthy controls were recruited from Guangdong Provincial People's Hospital. Demographic data was collected for all participants. Their SSR and CSP were evaluated using clinical electromyography equipment. Data were compared between different groups. The diagnostic accuracy of SSR and CSP parameters was calculated using the ROC curve. Logistic regression was used to produce an integration model to enhance diagnostic utility. RESULTS: Foot amplitude, CSP end latency and duration distinguished MSA-P from PD with the area under the curve (AUC) 0.770, 0.806, and 0.776, respectively. Foot and hand SSR amplitude distinguished PD from HC with the AUC 0.871 and 0.768, respectively. Foot SSR amplitude, hand SSR amplitude, and CSP end latency distinguished MSA-P from HC with the AUC 0.964, 0.872, and 0.812, respectively. The combination of SSR and CSP parameters differentiation between MSA-P and PD, PD and HC with the AUC 0.829 and 0.879, respectively. CONCLUSIONS: Analysis of SSR and CSP parameters showed excellent diagnostic accuracy in discriminating patients with early-stage MSA-P from HC and good diagnostic accuracy in discriminating patients with MSA-P from PD with early stages.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE