RESEARCH / DISCOVERY
← Back to the library

Safety and efficacy of unilateral focused ultrasound pallidotomy on motor complications in Parkinson's disease (PD): a systematic review and meta-analysis.

Safety and efficacy of unilateral focused ultrasound pallidotomy on motor complications in Parkinson's disease (PD): a systematic review and meta-analysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Damietta, EG · Author affiliation

Faculty of Medicine, Al-Azhar University, Damietta, Egypt. abdallah.abdelmoneam.abbas@gmail.com.
Location evidence

Alexandria, EG · Author affiliation

Faculty of Medicine, Alexandria University, Alexandria, Egypt.
Location evidence

EG · Author affiliation · country only

Faculty of Medicine, Benha University, Benha, Egypt.
Location evidence

Phoenix, US · Author affiliation

Department of Neurosurgery, University of Arizona College of Medicine, Phoenix, Arizona, United States.
Location evidence

Suez, EG · Author affiliation

MSc Faculty of Medicine, Suez Canal University, Ismailia, Egypt.
Location evidence

Ismailia, EG · Author affiliation

MSc Faculty of Medicine, Suez Canal University, Ismailia, Egypt.
Location evidence

Cairo, EG · Author affiliation

Department of Neurology, Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
Location evidence

Oregon, US · Author affiliation

Department of Neurological Surgery, Oregon Health & Science University, Portland, OR, United States.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

To systematically review and conduct a meta-analysis to evaluate the safety and efficacy of the unilateral focused ultrasound (FUS) pallidotomy on motor complications in Parkinson's disease (PD) patients. A comprehensive search strategy was implemented through August 15, 2023, and updated on February 13, 2024, across six databases, identifying studies relevant to unilateral focused ultrasound pallidotomy and PD. Eligibility criteria included observational studies, clinical trials, and case series reporting on the impact of the intervention on motor complications in PD patients. The screening and data extraction were done by two independent reviewers. Risk of bias assessment utilized appropriate tools for different study designs. Statistical analysis involved narrative synthesis and meta-analysis. Subgroup analyses and leave-one-out analyses were performed. Five studies were included in our study, involving 112 PD patients undergoing FUS pallidotomy. UPDRS-II analysis revealed a significant improvement from baseline (mean difference (MD): -3.205, 95% CI: -4.501, -1.909, P < 0.001). UPDRS-III overall change was significant (MD: -10.177, 95% CI: [-12.748, -7.606], P < 0.001). UPDRS-IV showed a significant change from baseline (MD: -5.069, 95% CI: [-5.915, -4.224], P < 0.001). UDysRS demonstrated a significant overall improvement (MD: -18.895, 95% CI: [-26.973, -10.818], P < 0.001). The effect of FUS pallidotomy on motor complications in PD patients was effective, with a significant decrease in the UPDRS and UDysRS, reflecting improvement. The incidence of adverse events (headaches, pin-site pain, difficulty walking, and sonication-related head pain) of the FUS pallidotomy was not statistically significant, indicating its safety.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE