RESEARCH / DISCOVERY
← Back to the library

Real-World Gait Detection Using a Wrist-Worn Inertial Sensor: Validation Study.

Real-World Gait Detection Using a Wrist-Worn Inertial Sensor: Validation Study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Basel, CH · Author affiliation

Novartis Biomedical Research, Novartis Pharma AG, Basel, Switzerland.
Location evidence

Tel Aviv, IL · Author affiliation

Department of Biomedical Engineering, Tel Aviv University, Tel Aviv, Israel.
Location evidence

Newcastle upon Tyne, GB · Author affiliation

Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, United Kingdom.
Location evidence

Turin, IT · Author affiliation

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.
Location evidence

Bologna, IT · Author affiliation

Department of Electrical, Electronic and Information Engineering, University of Bologna, Bologna, Italy.
Location evidence

Sheffield, GB · Author affiliation

Department of Mechanical Engineering and Insigneo Institute for In Silico Medicine, The University of Sheffield, Sheffield, United Kingdom.
Location evidence

Erlangen, DE · Author affiliation

Machine Learning and Data Analytics Lab, Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Location evidence

Lausanne, CH · Author affiliation

Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.
Location evidence

Stuttgart, DE · Author affiliation

Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.
Location evidence

Heidelberg, DE · Author affiliation

Unit Digitale Geriatrie, Universitätsklinikum Heidelberg, Heidelberg, Germany.
Location evidence

Barcelona, ES · Author affiliation

Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.
Location evidence

Madrid, ES · Author affiliation

CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.
Location evidence

Dublin, IE · Author affiliation

Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.
Location evidence

The Hague, NL · Author affiliation

McRoberts BV, The Hague, Netherlands.
Location evidence

Kiel, DE · Author affiliation

Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.
Location evidence

Chicago, US · Author affiliation

Rush Alzheimer's Disease Center, Rush University Medical Center, Chicago, IL, United States.
Location evidence

Trondheim, NO · Author affiliation

Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.