3D-CAM: a novel context-aware feature extraction framework for neurological disease classification.
3D-CAM: a novel context-aware feature extraction framework for neurological disease classification.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Shenyang, CN · Author affiliation
State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, China.Location evidence
CN · Author affiliation · country only
University of Chinese Academy of Sciences, Beiing, China.Location evidence
Beijing, CN · Author affiliation
Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China.Location evidence
Jiangnan, CN · Author affiliation
Department of Neurosurgery, Affiliated Hospital of Jiangnan University, Wuxi, China.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
In clinical practice and research, the classification and diagnosis of neurological diseases such as Parkinson's Disease (PD) and Multiple System Atrophy (MSA) have long posed a significant challenge. Currently, deep learning, as a cutting-edge technology, has demonstrated immense potential in computer-aided diagnosis of PD and MSA. However, existing methods rely heavily on manually selecting key feature slices and segmenting regions of interest. This not only increases subjectivity and complexity in the classification process but also limits the model's comprehensive analysis of global data features. To address this issue, this paper proposes a novel 3D context-aware modeling framework, named 3D-CAM. It considers 3D contextual information based on an attention mechanism. The framework, utilizing a 2D slicing-based strategy, innovatively integrates a Contextual Information Module and a Location Filtering Module. The Contextual Information Module can be applied to feature maps at any layer, effectively combining features from adjacent slices and utilizing an attention mechanism to focus on crucial features. The Location Filtering Module, on the other hand, is employed in the post-processing phase to filter significant slice segments of classification features. By employing this method in the fully automated classification of PD and MSA, an accuracy of 85.71%, a recall rate of 86.36%, and a precision of 90.48% were achieved. These results not only demonstrates potential for clinical applications, but also provides a novel perspective for medical image diagnosis, thereby offering robust support for accurate diagnosis of neurological diseases.