RESEARCH / DISCOVERY
← Back to the library

Intelligent wearable system with accurate detection of abnormal gait and timely cueing for mobility enhancement of people with Parkinson's disease.

Intelligent wearable system with accurate detection of abnormal gait and timely cueing for mobility enhancement of people with Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Guangzhou, CN · Author affiliation

School of Civil Engineering and Transportation, South China University of Technology, Guangzhou, China.
Location evidence

Hong Kong, HK · Author affiliation

Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong, China.
Location evidence

Jiangmen, CN · Author affiliation

School of Textile Materials and Engineering, Wuyi University, Jiangmen, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Previously reported wearable systems for people with Parkinson's disease (PD) have been focused on the detection of abnormal gait. They suffered from limited accuracy, large latency, poor durability, comfort, and convenience for daily use. Herewith we report an intelligent wearable system (IWS) that can accurately detect abnormal gait in real-time and provide timely cueing for PD patients. The system features novel sensitive, comfortable and durable plantar pressure sensing insoles with a highly compressed data set, an accurate and fast gait algorithm, and wirelessly controlled timely sensory cueing devices. A total of 29 PD patients participated in the first phase without cueing for developing processes of the algorithm, which achieved an accuracy of over 97% for off-line detection of freezing of gait (FoG). In the second phase with cueing, the evaluation of the whole system was conducted with 16 PD subjects via trial and a questionnaire survey. This system demonstrated an accuracy of 94% for real-time detection of FoG and a mean latency of 0.37 s between the onset of FoG and cueing activation. In questionnaire survey, 88% of the PD participants confirmed that this wearable system could effectively enhance walking, 81% thought that the system was comfortable and convenient, and 70% overcame the FoG. Therefore, the IWS makes it an effective, powerful, and convenient tool for enhancing the mobility of people with PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE