RESEARCH / DISCOVERY
← Back to the library

The validation of a Japanese version of the New Freezing of Gait Questionnaire (NFOG-Q).

The validation of a Japanese version of the New Freezing of Gait Questionnaire (NFOG-Q).

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Osaka, JP · Author affiliation

Department of Neurology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. seira.taniguchi.pt@gmail.com.
Location evidence

Suita, JP · Author affiliation

Department of Neurology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan. seira.taniguchi.pt@gmail.com.
Location evidence

Kotō, JP · Author affiliation

Hyogo Prefectural Rehabilitation Hospital at Nishi-Harima, 1-7-1 Koto, Shingu-Cho, Tatsuno, Hyogo, Japan.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: This study aimed to develop a Japanese version of the New Freezing of Gait Questionnaire (NFOG-Q) and investigate its validity and reliability. METHODS: After translating the NFOG-Q according to a standardised protocol, 56 patients with Parkinson's disease (PD) were administered it. Additionally, the MDS-UPDRS parts II and III, Hoehn and Yahr (H&Y) stage, and number of falls over 1 month were evaluated. Spearman's correlation coefficients (rho) were used to determine construct validity, and Cronbach's alpha (α) was used to examine reliability. RESULTS: The interquartile range of the NFOG-Q scores was 10.0-25.3 (range 0-29). The NFOG-Q scores were strongly correlated with the MDS-UPDRS part II, items 2.12 (walking and balance), 2.13 (freezing), 3.11 (freezing of gait), and 3.12 (postural stability) and the postural instability and gait difficulty score (rho = 0.515-0.669), but only moderately related to the MDS-UPDRS item 3.10 (gait), number of falls, disease duration, H&Y stage, and time of the Timed Up-and-Go test (rho = 0.319-0.434). No significant correlations were observed between age and the time of the 10-m walk test. The internal consistency was excellent (α = 0.96). CONCLUSIONS: The Japanese version of the NFOG-Q is a valid and reliable tool for assessing the severity of freezing in patients with PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE