New insight into interference-free and highly sensitive dopamine electroanalysis.

New insight into interference-free and highly sensitive dopamine electroanalysis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Ghāziābād, IN · Author affiliation

Electrochemical Process Engineering Division, CSIR-Central Electrochemical Research Institute, Karaikudi, 630003, Tamil Nadu, India; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Early diagnosis of Parkinson's disease and hyperprolactinemia based on electrochemical dopamine (DA) sensing appears as an efficient and promising practical diagnostic method. However, the coexistence of DA in real samples with ascorbic acid (AA) and uric acid (UA), which oxidize at potentials close to its own, prevents the accurate electrochemical DA sensing and therefore, hinders the effective diagnosis of these diseases. In this work, we successfully combined the electrostatic proprieties of GO, the electron transfer properties of an AuNPs@MWCNTs nanocomposite and the ability of thiol group of the amino acid l-cysteine to react chemically with carbonyl groups of UA, to develop a novel approach that enabled complete suppression of interference from AA and UA and hence, accurate DA electroanalysis in the conditions close to those of human blood serum. The chemical reaction between l-cysteine and UA was evidenced by monitoring the DPV responses of UA under different conditions. XRD, Raman spectroscopy, XPS and FE-SEM revealed the successful synthesis of GO and AuNPs@MWCNTs. The study of the electrode material (GO-AuNPs@MWCNTs) morphology via FE-SEM and HR-TEM showed that AuNPs@MWCNTs are distributed throughout the exfoliated GO layers. The fabricated sensor was calibrated in the concentration range of 0.5-5 μM, in the presence of the highest blood concentrations of AA and UA for healthy individuals. A linear relationship was observed and the LOD was found to be 1.31 nM (S/N = 3). Furthermore, the sensor showed good electron transfer kinetics, good repeatability and reproducibility, satisfactory long-term stability, and recoveries in human blood serum.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE