Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.
Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Newcastle upon Tyne, GB · Author affiliation
Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, The Catalyst 3 Science Square, Room 3.27, Newcastle Upon Tyne, NE4 5TG, UK.Location evidence
Erlangen, DE · Author affiliation
Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.Location evidence
Sheffield, GB · Author affiliation
Department of Mechanical Engineering and Insigneo Institute for in Silico Medicine, The University of Sheffield, Sheffield, UK.Location evidence
Lausanne, CH · Author affiliation
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.Location evidence
Tel Aviv, IL · Author affiliation
Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.Location evidence
Sassari, IT · Author affiliation
Department of Biomedical Sciences, University of Sassari, Sassari, Italy.Location evidence
Stuttgart, DE · Author affiliation
Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.Location evidence
Barcelona, ES · Author affiliation
Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.Location evidence
Madrid, ES · Author affiliation
CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.Location evidence
Turin, IT · Author affiliation
Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.Location evidence
Dublin, IE · Author affiliation
Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.Location evidence
Bologna, IT · Author affiliation
Department of Electrical, Electronic and Information Engineering «Guglielmo Marconi», University of Bologna, Bologna, Italy.Location evidence
Kiel, DE · Author affiliation
Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.Location evidence
Chicago, US · Author affiliation
Rush Alzheimer's Disease Center and Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.Location evidence
Basel, CH · Author affiliation
Novartis Institutes of Biomedical Research, Novartis Pharma AG, Basel, Switzerland.Location evidence
The Hague, NL · Author affiliation
McRoberts BV, The Hague, The Netherlands.Location evidence
SE · Author affiliation · country only
Digital Health R&D, AstraZeneca, Sweden.Location evidence
Trondheim, NO · Author affiliation
Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.