Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.

Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Newcastle upon Tyne, GB · Author affiliation

Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, The Catalyst 3 Science Square, Room 3.27, Newcastle Upon Tyne, NE4 5TG, UK.
Location evidence

Erlangen, DE · Author affiliation

Machine Learning and Data Analytics Lab, Department Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Location evidence

Sheffield, GB · Author affiliation

Department of Mechanical Engineering and Insigneo Institute for in Silico Medicine, The University of Sheffield, Sheffield, UK.
Location evidence

Lausanne, CH · Author affiliation

Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.
Location evidence

Tel Aviv, IL · Author affiliation

Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Location evidence

Sassari, IT · Author affiliation

Department of Biomedical Sciences, University of Sassari, Sassari, Italy.
Location evidence

Stuttgart, DE · Author affiliation

Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.
Location evidence

Barcelona, ES · Author affiliation

Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.
Location evidence

Madrid, ES · Author affiliation

CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.
Location evidence

Turin, IT · Author affiliation

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.
Location evidence

Dublin, IE · Author affiliation

Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.
Location evidence

Bologna, IT · Author affiliation

Department of Electrical, Electronic and Information Engineering «Guglielmo Marconi», University of Bologna, Bologna, Italy.
Location evidence

Kiel, DE · Author affiliation

Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.
Location evidence

Chicago, US · Author affiliation

Rush Alzheimer's Disease Center and Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Location evidence

Basel, CH · Author affiliation

Novartis Institutes of Biomedical Research, Novartis Pharma AG, Basel, Switzerland.
Location evidence

The Hague, NL · Author affiliation

McRoberts BV, The Hague, The Netherlands.
Location evidence

SE · Author affiliation · country only

Digital Health R&D, AstraZeneca, Sweden.
Location evidence

Trondheim, NO · Author affiliation

Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.