RESEARCH / DISCOVERY
← Back to the library

Validity and reliability of linear encoder muscle power testing in persons with Parkinson's disease.

Validity and reliability of linear encoder muscle power testing in persons with Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

DK · Author affiliation · country only

Exercise Biology, Department of Public Health, Aarhus University, Aarhus, Denmark.
Location evidence

Viborg, DK · Author affiliation

Department of Neurology, Viborg Regional Hospital, Viborg, Denmark.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: To investigate the construct validity ON medication and the reliability both ON and OFF medication of linear encoder muscle power testing in persons with Parkinson's disease (pwPD). DESIGN: A study using baseline data from one randomized controlled trial (study 1) and one cohort study (study 2). SETTING: University exercise lab. PARTICIPANTS: Study 1: 35 healthy controls and 70 pwPD. Study 2: 20 pwPD. INTERVENTION: Study 1: baseline data. Study 2: 4 chair rise tests (2 ON and 2 OFF medication), in a randomized order, separated by 4 to 16 days. MAIN MEASURES: Linear encoder data were collected from a chair rise test. Known groups validity and convergent validity (i.e., construct validity) were assessed by comparing peak power between pwPD and healthy controls and associations between peak power and functional performance (i.e., 6-Min Walk Test, Timed Up and Go Test, Six-Spot Step Test), respectively. Reliability was assessed as day-to-day variation and by intraclass correlation coefficients. RESULTS: Peak power was comparable between pwPD and healthy controls (-7.2%, p = 0.17), but lower in moderately impaired pwPD compared to mildly impaired pwPD (-27%, p < 0.01) and healthy controls (-23%, p < 0.01). Moderate to strong associations were observed between peak power and functional performance (r2 = 0.44-0.51). Day-to-day variation ON and OFF medication were 1.0 and 1.3 W/kg, respectively, while intraclass correlation coefficients were 0.95 (0.87;0.98) and 0.93 (0.82;0.97), respectively. CONCLUSION: Linear encoder muscle power testing shows inconsistent known groups validity, acceptable convergent validity ON medication, and excellent day-to-day reliability ON and OFF medication in pwPD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE