Four Days Are Enough to Provide a Reliable Daily Step Count in Mild to Moderate Parkinson's Disease through a Commercial Smartwatch.
Four Days Are Enough to Provide a Reliable Daily Step Count in Mild to Moderate Parkinson's Disease through a Commercial Smartwatch.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Rome, IT · Author affiliation
Department of Neuroscience, Mental Health and Sensory Organs (NESMOS), Sapienza University of Rome, 00189 Rome, Italy.Location evidence
Grenoble, FR · Author affiliation
AGEIS, Université Grenoble Alpes, 38000 Grenoble, France.Location evidence
Kiel, DE · Author affiliation
Department of Neurology, Kiel University, 24105 Kiel, Germany.Location evidence
Orange, FR · Author affiliation
LabCom Telecom4Health, Orange Labs & Université Grenoble Alpes, CNRS, Inria, Grenoble INP-UGA, 38000 Grenoble, France.Location evidence
Paris, FR · Author affiliation
Institut Universitaire de France, 75005 Paris, France.Location evidence
IT · Author affiliation · country only
IRCCS Neuromed Institute, 86077 Pozzilli, Italy.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Daily steps could be a valuable indicator of real-world ambulation in Parkinson's disease (PD). Nonetheless, no study to date has investigated the minimum number of days required to reliably estimate the average daily steps through commercial smartwatches in people with PD. Fifty-six patients were monitored through a commercial smartwatch for 5 consecutive days. The total daily steps for each day was recorded and the average daily steps was calculated as well as the working and weekend days average steps. The intraclass correlation coefficient (ICC) (3,k), standard error of measurement (SEM), Bland-Altman statistics, and minimum detectable change (MDC) were used to evaluate the reliability of the step count for every combination of 2-5 days. The threshold for acceptability was set at an ICC ≥ 0.8 with a lower bound of CI 95% ≥ 0.75 and a SAM < 10%. ANOVA and Mann-Whitney tests were used to compare steps across the days and between the working and weekend days, respectively. Four days were needed to achieve an acceptable reliability (ICC range: 0.84-0.90; SAM range: 7.8-9.4%). In addition, daily steps did not significantly differ across the days and between the working and weekend days. These findings could support the use of step count as a walking activity index and could be relevant to developing monitoring, preventive, and rehabilitation strategies for people with PD.