Simple quantitative planimetric measurement of nigrosome-1 for clinical settings.

Simple quantitative planimetric measurement of nigrosome-1 for clinical settings.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Adelaide, AU · Author affiliation

UniSA Allied Health & Human Performance and Alliance for Research in Exercise, Nutrition and Activity (ARENA), City East Campus, University of South Australia, GPO Box 2471, Adelaide, SA 5001, Australia; South Australia Medical Imaging, Flinders Medical Centre, 1 Flinders Drive, Bedford Park, SA 5042, Australia.
Location evidence

AU · Author affiliation · country only

South Australia Medical Imaging, Flinders Medical Centre, 1 Flinders Drive, Bedford Park, SA 5042, Australia; College of Medicine and Public Health, Flinders University, 1 Flinders Drive, Bedford Park, SA 5042, Australia.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Loss of MRI hyperintense signal in nigrosome-1 (assessed with susceptibility-weighted imaging) is a biomarker for Parkinson's disease (PD). Current clinical practice involves subjectively rating the appearance of nigrosome-1 which is challenging. The study aimed to test and compare a simple method for quantifying nigrosome-1 with the current subjective rating method. METHODS: Two experienced neuroradiologists measured area of hyperintense signal in nigrosome-1 (quantitative method) and rated nigrosome-1 appearance (as normal, attenuated, or absent; subjective method) in 42 patients encompassing the full spectrum of nigrosome-1 integrity (21 patients aged 55.5 ± 20.9 years with Essential tremor (ET) and a subset of 21 patients aged 69.6 ± 8.6 years with PD). Neuroradiologists were blinded to each other's measurements, clinical notes, and patient group. RESULTS: Both methods yielded a significant difference between the groups (PD vs ET; p < 0.001). Pooled (across sides) area of nigrosome-1 hyperintense signal was significantly smaller in the PD group (median = 2.1 mm2, range = 0-15.8 mm2) than ET group (median = 8.3 mm2, range = 0-15.7 mm2; p < 0.001). Inter-rater reliability was high to very high for both methods (subjective: weighted kappa = 0.640, p < 0.001; quantitative: W = 0.733, p = 0.004). Our primary hypothesis that area of nigrosome-1 hyperintense signal exhibits higher inter-rater reliability than subjective rating of nigrosome-1 appearance was not supported. CONCLUSION: The simple quantitative method, used with subjectively rated nigrosome-1 appearance, may improve confidence in longitudinal clinical reporting, when nigrosome-1 is attenuated. However, further work on the incremental diagnostic value of planimetry and bias, repeatability and reproducibility are needed before it can be recommended in clinical practice.