RESEARCH / DISCOVERY
← Back to the library

A novel intramolecular charge transfer-based near-infrared fluorescent probe with large Stokes shift for highly sensitive detection of cysteine in vivo.

A novel intramolecular charge transfer-based near-infrared fluorescent probe with large Stokes shift for highly sensitive detection of cysteine in vivo.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Jilin, CN · Author affiliation

Department of Plastic and Reconstructive Microsurgery, China-Japan Union Hospital, Jilin University, Xiantai Street 126, Changchun, 130033, PR China.
Location evidence

Changchun, CN · Author affiliation

Department of Plastic and Reconstructive Microsurgery, China-Japan Union Hospital, Jilin University, Xiantai Street 126, Changchun, 130033, PR China.
Location evidence

JP · Author affiliation · country only

Department of Plastic and Reconstructive Microsurgery, China-Japan Union Hospital, Jilin University, Xiantai Street 126, Changchun, 130033, PR China.
Location evidence

Beijing, CN · Author affiliation

School of Nursing, Peking University, Xueyuan Street 38, Beijing, 100191, PR China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Cysteine (Cys) distribute widely in organisms as the crucial components of proteins, and play important roles in pathophysiological processes of human body. Low level of Cys might induce hepatic injury, edema and growth retardation, while superfluous level of Cys is found to be closely relevant to Alzheimer's and Parkinson's diseases. In this work, a novel near-infrared (NIR) fluorescent probe PFQ-C was developed for highly selective detection of Cys in living cells and mice by utilizing the cyclization removal reaction between acrylate group and Cys. The superior sensitivity (limit of detection, 0.036 μM), NIR emission (655 nm), large Stokes shift (135 nm) and low cytotoxicity of the probe highlight its broad potential for future clinical applications. The response mechanism of the probe towards Cys was clarified by spectroscopy, chromatography and theoretical calculation. In addition, results of fluorescence imaging of cells and mice revealed the good performance of the probe for monitoring the distributions and variations of Cys activity in vivo, which is very useful for the researches on diseases associated with Cys.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE