RESEARCH / DISCOVERY
← Back to the library

Nacre-Inspired MXene Nanocomposite-based Strain Sensor with Ultrahigh Sensitivity in a Small Strain Range for Parkinson's Disease Diagnosis.

Nacre-Inspired MXene Nanocomposite-based Strain Sensor with Ultrahigh Sensitivity in a Small Strain Range for Parkinson's Disease Diagnosis.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

CN · Author affiliation · country only

Shaanxi Key Laboratory of Macromolecular Science and Technology, School of Chemistry and Chemical Engineering, Northwestern Polytechnical University, Xi'an 710072, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Nowadays, chronic diseases are the primary threat to public health and are getting younger. By taking the advantages of continuousness, convenience, and real-time response, wearable strain sensors have been given great attention to diagnose chronic diseases via analyzing the patient's health state. However, most physiological signals, such as limb tremor of Parkinson's disease, microexpression, and slight joint movement, are tiny and difficult to be detected. Therefore, the development of strain sensors characterized with ultrahigh sensitivity in a small strain range (ε < 10%) is urgent. Inspired by nacre's hierarchical structure, we have fabricated nacre-mimetic nanocomposites with "brick-and-mortar" architecture by employing polyacrylamide (PAM) and Ti3C2Tx MXene nanosheets through a layer-by-layer (LBL) spin-coating technique. The resultant nanocomposite-based strain sensor exhibits ultrahigh sensitivity in a small strain range (GF = 296.8, ε < 10%), attributed to the bioinspired hierarchical structure and hydrogen bond-enhanced interfacial interactions. In addition, a high reliability, broad working sensing range (453%), short response time (183 ms), skin-like tensile stress (7.2 MPa), and excellent durability (2000 cycles) are also achieved. Due to the ultrahigh sensitivity within a small strain, the reported strain sensor can accurately diagnose and distinguish Parkinson's disease symptoms, including thumb pill-rolling tremor, masked face (microexpression), intermittent shaking of the head, and limb cogwheel motion. This work provides new insights to design strain sensors with high sensitivity for monitoring tiny signals and for disease diagnosis.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE