Modified Neuropixels probes for recording human neurophysiology in the operating room.
Modified Neuropixels probes for recording human neurophysiology in the operating room.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Boston, US · Author affiliation
Center for Neurotechnology and Neurorecovery, Department of Neurology, Massachusetts General Hospital, Boston, MA, USA.Location evidence
New York City, US · Author affiliation
Department of Neuroscience, Columbia University Medical Center, New York, NY, USA.Location evidence
Davis, US · Author affiliation
Department of Neurological Surgery, University of California Davis, Davis, CA, USA.Location evidence
US · Author affiliation · country only
Department of Neurosurgery, Stanford University, Stanford, CA, USA.Location evidence
Howard, US · Author affiliation
Howard Hughes Medical Institute at Stanford University, Stanford, CA, USA.Location evidence
Leuven, BE · Author affiliation
imec, Leuven, Belgium.Location evidence
Providence, US · Author affiliation
VA RR&D Center for Neurorestoration and Neurotechnology, Rehabilitation R&D Service, Providence VA Medical Center, Providence, RI, USA.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Neuropixels are silicon-based electrophysiology-recording probes with high channel count and recording-site density. These probes offer a turnkey platform for measuring neural activity with single-cell resolution and at a scale that is beyond the capabilities of current clinically approved devices. Our team demonstrated the first-in-human use of these probes during resection surgery for epilepsy or tumors and deep brain stimulation electrode placement in patients with Parkinson's disease. Here, we provide a better understanding of the capabilities and challenges of using Neuropixels as a research tool to study human neurophysiology, with the hope that this information may inform future efforts toward regulatory approval of Neuropixels probes as research devices. In perioperative procedures, the major concerns are the initial sterility of the device, maintaining a sterile field during surgery, having multiple referencing and grounding schemes available to de-noise recordings (if necessary), protecting the silicon probe from accidental contact before insertion and obtaining high-quality action potential and local field potential recordings. The research team ensures that the device is fully operational while coordinating with the surgical team to remove sources of electrical noise that could otherwise substantially affect the signals recorded by the sensitive hardware. Prior preparation using the equipment and training in human clinical research and working in operating rooms maximize effective communication within and between the teams, ensuring high recording quality and minimizing the time added to the surgery. The perioperative procedure requires ~4 h, and the entire protocol requires multiple weeks.