Validity and reliability of a new clinician-rated tool for freezing of gait severity.
Validity and reliability of a new clinician-rated tool for freezing of gait severity.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Perth, AU · Author affiliation
School of Allied Health, Curtin University, Bentley, Perth, Australia.Location evidence
Singapore, SG · Author affiliation
Health and Social Sciences, Singapore Institute of Technology, Singapore, Singapore.Location evidence
Frankston, AU · Author affiliation
Rehabilitation Ageing and Independent Living Research Centre, Monash University, Frankston, Australia.Location evidence
Sunshine Coast, AU · Author affiliation
School of Health and Behavioural Sciences, University of the Sunshine Coast, Sippy Downs, Australia.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
PURPOSE: The Freezing of Gait Severity Tool (FOG Tool) was developed because of limitations in existing assessments. This cross-sectional study investigated its validity and reliability. METHODS: People with Parkinson's disease (PD) were recruited consecutively from clinics. Those who could not walk eight-metres independently (with or without an assistive device), comprehend instructions, or with co-morbidities affecting walking were excluded. Participants completed a set of assessments including the FOG Tool, Timed Up and Go (TUG), and Freezing of Gait Questionnaire. The FOG Tool was repeated and those reporting no medication state change evaluated for test-retest reliability. Validity and reliability were investigated through Spearman's correlations and ICC (two-way, random). McNemar's test was applied to compare the FOG Tool and TUG on the proportion of people with freezing. RESULTS: Thirty-nine participants were recruited [79.5%(n = 31) male; Median(IQR): age-73.0(9.0) years; disease duration-4.0(5.8) years]. Fifteen (38.5%) contributed to test-retest reliability analyses. The FOG Tool demonstrated strongest associations with the Freezing of Gait Questionnaire (ρ = 0.67, 95%CI 0.43-0.83). Test-retest reliability was excellent (ICC = 0.96, 95%CI 0.88-0.99). The FOG Tool had 6.2 times the odds (95%CI 2.4-20.4, p < 0.001) of triggering freezing compared to the TUG. CONCLUSIONS: The FOG Tool appeared adequately valid and reliable in this small sample of people with PD. It was more successful in triggering freezing than the TUG.