RESEARCH / DISCOVERY
← Back to the library

Validity and reliability of a new clinician-rated tool for freezing of gait severity.

Validity and reliability of a new clinician-rated tool for freezing of gait severity.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Perth, AU · Author affiliation

School of Allied Health, Curtin University, Bentley, Perth, Australia.
Location evidence

Singapore, SG · Author affiliation

Health and Social Sciences, Singapore Institute of Technology, Singapore, Singapore.
Location evidence

Frankston, AU · Author affiliation

Rehabilitation Ageing and Independent Living Research Centre, Monash University, Frankston, Australia.
Location evidence

Sunshine Coast, AU · Author affiliation

School of Health and Behavioural Sciences, University of the Sunshine Coast, Sippy Downs, Australia.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

PURPOSE: The Freezing of Gait Severity Tool (FOG Tool) was developed because of limitations in existing assessments. This cross-sectional study investigated its validity and reliability. METHODS: People with Parkinson's disease (PD) were recruited consecutively from clinics. Those who could not walk eight-metres independently (with or without an assistive device), comprehend instructions, or with co-morbidities affecting walking were excluded. Participants completed a set of assessments including the FOG Tool, Timed Up and Go (TUG), and Freezing of Gait Questionnaire. The FOG Tool was repeated and those reporting no medication state change evaluated for test-retest reliability. Validity and reliability were investigated through Spearman's correlations and ICC (two-way, random). McNemar's test was applied to compare the FOG Tool and TUG on the proportion of people with freezing. RESULTS: Thirty-nine participants were recruited [79.5%(n = 31) male; Median(IQR): age-73.0(9.0) years; disease duration-4.0(5.8) years]. Fifteen (38.5%) contributed to test-retest reliability analyses. The FOG Tool demonstrated strongest associations with the Freezing of Gait Questionnaire (ρ = 0.67, 95%CI 0.43-0.83). Test-retest reliability was excellent (ICC = 0.96, 95%CI 0.88-0.99). The FOG Tool had 6.2 times the odds (95%CI 2.4-20.4, p < 0.001) of triggering freezing compared to the TUG. CONCLUSIONS: The FOG Tool appeared adequately valid and reliable in this small sample of people with PD. It was more successful in triggering freezing than the TUG.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE