RESEARCH / DISCOVERY
← Back to the library

Three-dimensional gait analysis of the effect of directional steering on gait in patients with Parkinson's disease.

Three-dimensional gait analysis of the effect of directional steering on gait in patients with Parkinson's disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Tokyo, JP · Author affiliation

Department of Neurology, Juntendo University School of Medicine, Tokyo, Japan.
Location evidence

Quezon City, PH · Author affiliation

Department of Neurology, St. Luke's Medical Center, Quezon City, Philippines.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Deep Brain Stimulation (DBS) is an option to treat advanced Parkinson's Disease (PD), but can cause gait disturbance due to stimulation side efffects. This study aims to evaluate the objective effect of directional current steering by DBS on gait performance in PD, utilizing a three-dimensional gait analysis system. METHODS: Eleven patients diagnosed with PD and were implanted with directional lead were recruited. The direction of the pyramidal tract (identified by the directional mode screening) was set as 0°. Patients performed the six-meter-walk test and the time up-and-go (TUG) test while an analysis system recorded gait parameters utilizing a three-dimensional motion capture camera. The gait parameters were measured for the baseline, the directional steering at eight angles (0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°), and the conventional ring mode with 1, 2, and 3 mA. Pulse width and frequency were fixed. Placebo stimulation (0 mA) was used for a control. RESULTS: Eleven patients completed the study. No significant difference were observed between gait parameters during the directional, baseline, placebo, or ring modes during the six-meter-walk test (p > 0.05). During the TUG test, stride length was significantly different between 0° and other directions (p < 0.001), but no significant differences were observed for the other gait parameters. Stride width was non-significantly narrower in the direction of 0°. CONCLUSION: Controlling stimulation using directional steering may improve gait in patients with PD, while avoiding pyramidal side effects.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE