RESEARCH / DISCOVERY
← Back to the library

Wearable multisource quantitative gait analysis of Parkinson's diseases.

Wearable multisource quantitative gait analysis of Parkinson's diseases.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

CN · Author affiliation · country only

Key Laboratory of Education Ministry for Modern Design and Rotor-Bearing System, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, 710049, China.
Location evidence

Hong Kong, HK · Author affiliation

Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong, 999077, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

As the motor symptoms of Parkinson's disease (PD) are complex and influenced by many factors, it is challenging to quantify gait abnormalities adequately using a single type of signal. Therefore, a wearable multisource gait monitoring system is developed to perform a quantitative analysis of gait abnormalities for improving the effectiveness of the clinical diagnosis. To detect multisource gait data for an accurate evaluation of gait abnormalities, force sensitive sensors, piezoelectric sensors, and inertial measurement units are integrated into the devised device. The modulation circuits and wireless framework are designed to simultaneously collect plantar pressure, dynamic deformation, and postural angle of the foot and then wirelessly transmit these collected data. With the designed system, multisource gait data from PD patients and healthy controls are collected. Multisource features for quantifying gait abnormalities are extracted and evaluated by a significance test of difference and correlation analysis. The results show that the features extracted from every single type of data are able to quantify the health status of the subjects (p < 0.001, ρ > 0.50). More importantly, the validity of multisource gait data is verified. The results demonstrate that the gait feature fusing multisource data achieves a maximum correlation coefficient of 0.831, a maximum Area Under Curve of 0.9206, and a maximum feature-based classification accuracy of 88.3%. The system proposed in this study can be applied to the gait analysis and objective evaluation of PD.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE