Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium.
Assessing real-world gait with digital technology? Validation, insights and recommendations from the Mobilise-D consortium.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Newcastle upon Tyne, GB · Author affiliation
Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK.Location evidence
Sheffield, GB · Author affiliation
Department of Mechanical Engineering and Insigneo Institute for in Silico Medicine, The University of Sheffield, Sheffield, UK.Location evidence
Lausanne, CH · Author affiliation
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.Location evidence
Erlangen, DE · Author affiliation
Machine Learning and Data Analytics Lab, Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.Location evidence
Tel Aviv, IL · Author affiliation
Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.Location evidence
Sassari, IT · Author affiliation
Department of Biomedical Sciences, University of Sassari, Sassari, Italy.Location evidence
Turin, IT · Author affiliation
Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.Location evidence
Stuttgart, DE · Author affiliation
Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.Location evidence
Barcelona, ES · Author affiliation
Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.Location evidence
Madrid, ES · Author affiliation
CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.Location evidence
Dublin, IE · Author affiliation
Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.Location evidence
Bologna, IT · Author affiliation
Department of Electrical, Electronic and Information Engineering «Guglielmo Marconi», University of Bologna, Bologna, Italy.Location evidence
Aachen, DE · Author affiliation
Grünenthal GmbH, Aachen, Germany.Location evidence
Kiel, DE · Author affiliation
Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.Location evidence
Chicago, US · Author affiliation
Rush Alzheimer's Disease Center and Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA.Location evidence
Basel, CH · Author affiliation
Novartis Institutes of Biomedical Research, Novartis Pharma AG, Basel, Switzerland.Location evidence
The Hague, NL · Author affiliation
McRoberts BV, The Hague, Netherlands.Location evidence
Stockholm, SE · Author affiliation
Digital Health R&D, AstraZeneca, Stockholm, Sweden.Location evidence
Trondheim, NO · Author affiliation
Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.Location evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.