RESEARCH / DISCOVERY
← Back to the library

Ikelos-RWA. Validation of an Automatic Tool to Quantify REM Sleep Without Atonia.

Ikelos-RWA. Validation of an Automatic Tool to Quantify REM Sleep Without Atonia.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Berlin, DE · Author affiliation

Sleep Research & Clinical Chronobiology, Institute of Physiology, Charité - Universitätsmedizin Berlin, Corporate Member of Freien Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Location evidence

Göttingen, DE · Author affiliation

Department of Ophthalmology, University Medical Center Goettingen, Göttingen, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Study Objectives. To present and evaluate an automatic scoring algorithm for quantification of REM-sleep without atonia (RWA) in patients with REM-sleep behaviour disorder (RBD) based on a generally accepted, well-validated visual scoring method, ("Montreal" phasic and tonic) and a recently developed, concise scoring method (Ikelos-RWA). Methods. Video-polysomnographies of 20 RBD patients (68.2 ± 7.2 years) and 20 control patients with periodic limb movement disorder (65.9 ± 6.7 years) were retrospectively analysed. RWA was estimated from chin electromyogram during REM-sleep. Visual and automated RWA scorings were correlated, and agreement (a) and Cohen's Kappa (k) calculated for 1735 minutes of REM-sleep of the RBD patients. Discrimination performance was evaluated with receiver operating characteristic (ROC) analysis. The algorithm was then applied on the polysomnographies of a cohort of 232 RBD patients (total analysed REM-sleep: 17,219 minutes) and evaluated, while correlating the different output parameters. Results. Visual and computer-derived RWA scorings correlated significantly (tonic Montreal: rTM = 0.77; phasic Montreal: rPM = 0.78; Ikelos-RWA: rI = 0.97; all p < 0.001) and showed good to excellent Kappa coefficients (kTM = 0.71; kPM = 0.79; kI = 0.77). The ROC analysis showed high sensitivities (95%-100%) and specificities (84%-95%) at the optimal operation points, with area under the curve (AUC) of 0.98, indicating high discriminating capacity. The automatic RWA scorings of 232 patients correlated significantly (rTM{I} = 0.95; rPM{I} = 0.91, p < 0.0001). Conclusions. The presented algorithm is an easy-to-use and valid tool for automatic RWA scoring in patients with RBD and may prove effective for general use being publicly available.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE