RESEARCH / DISCOVERY
← Back to the library

Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove.

Learning Hand Kinematics for Parkinson's Disease Assessment Using a Multimodal Sensor Glove.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Changchun, CN · Author affiliation

School of Life Science and Technology, Changchun University of Science and Technology, Changchun, 130022, P. R. China.
Location evidence

Los Angeles, US · Author affiliation

Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA.
Location evidence

Singapore, SG · Author affiliation

Department of Materials Science and Engineering, National University of Singapore, Singapore, 117583, Singapore.
Location evidence

Vancouver, CA · Author affiliation

Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, V6T1Z4, Canada.
Location evidence

Jilin, CN · Author affiliation

China-Japan Union Hospital of Jilin University, Changchun, 130033, P. R. China.
Location evidence

JP · Author affiliation · country only

China-Japan Union Hospital of Jilin University, Changchun, 130033, P. R. China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Hand dysfunctions in Parkinson's disease include rigidity, muscle weakness, and tremor, which can severely affect the patient's daily life. Herein, a multimodal sensor glove is developed for quantifying the severity of Parkinson's disease symptoms in patients' hands while assessing the hands' multifunctionality. Toward signal processing, various algorithms are used to quantify and analyze each signal: Exponentially Weighted Average algorithm and Kalman filter are used to filter out noise, normalization to process bending signals, K-Means Cluster Analysis to classify muscle strength grades, and Back Propagation Neural Network to identify and classify tremor signals with an accuracy of 95.83%. Given the compelling features, the flexibility, muscle strength, and stability assessed by the glove and the clinical observations are proved to be highly consistent with Kappa values of 0.833, 0.867, and 0.937, respectively. The intraclass correlation coefficients obtained by reliability evaluation experiments for the three assessments are greater than 0.9, indicating that the system is reliable. The glove can be applied to assist in formulating targeted rehabilitation treatments and improve hand recovery efficiency.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE