RESEARCH / DISCOVERY
← Back to the library

Sensing of Catecholamine in Human Urine Using a Simple Colorimetric Assay Based on Direct Melanochrome and Indolequinone Formation.

Sensing of Catecholamine in Human Urine Using a Simple Colorimetric Assay Based on Direct Melanochrome and Indolequinone Formation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Florence, IT · Author affiliation

Department of Chemistry 'Ugo Schiff', University of Florence, 50019 Sesto Fiorentino, Italy.
Location evidence

Sesto Fiorentino, IT · Author affiliation

Department of Chemistry 'Ugo Schiff', University of Florence, 50019 Sesto Fiorentino, Italy.
Location evidence

Naples, IT · Author affiliation

Department of Chemical Sciences, University of Naples Federico II, 80126 Naples, Italy.
Location evidence

Pisa, IT · Author affiliation

Laboratory of Clinical Pathology, University Hospital of Pisa, 56126 Pisa, Italy.
Location evidence

Rome, IT · Author affiliation

INBB-Istituto Nazionale Biostrutture e Biosistemi, Consorzio Interuniversitario, 00136 Rome, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

We used the first enzyme-free synthesis and stabilization of soluble melanochrome (MC) and 5,6-indolequinone (IQ) derived from levodopa (LD), dopamine (DA), and norepinephrine (NE) oxidation to develop a simple colorimetric assay for catecholamine detection in human urine, also elucidating the time-dependent formation and molecular weight of MC and IQ using UV-Vis spectroscopy and mass spectrometry. The quantitative detection of LD and DA was achieved in human urine using MC as a selective colorimetric reporter to demonstrate the potential assay applicability in a matrix of interest in therapeutic drug monitoring (TDM) and in clinical chemistry. The assay showed a linear dynamic range between 5.0 mg L-1 and 50.0 mg L-1, covering the concentration range of DA and LD found in urine samples from, e.g., Parkinson's patients undergoing LD-based pharmacological therapy. The data reproducibility in the real matrix was very good within this concentration range (RSDav% 3.7% and 6.1% for DA and LD, respectively), also showing very good analytical performances with the limits of detection of 3.69 ± 0.17 mg L-1 and 2.51 ± 0.08 mg L-1 for DA and LD, respectively, thus paving the way for the effective and non-invasive monitoring of dopamine and levodopa in urine from patients during TDM in Parkinson's disease.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE