RESEARCH / DISCOVERY
← Back to the library

Reliability and validity of visual analysis of [ 18 F]FE-PE2I PET/CT in early Parkinsonian disease.

Reliability and validity of visual analysis of [ 18 F]FE-PE2I PET/CT in early Parkinsonian disease.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Umeå, SE · Author affiliation

Department of Radiation Sciences, Diagnostic Radiology, Umeå University, Umeå, Sweden.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

OBJECTIVE: [ 18 F]FE-PE2I (FE-PE2I) is a new radiotracer for dopamine transporter (DAT) imaging with PET. The aim of this study was to evaluate the visual interpretation of FE-PE2I images for the diagnosis of idiopathic Parkinsonian syndrome (IPS). The inter-rater variability, sensitivity, specificity, and diagnostic accuracy for visual interpretation of striatal FE-PE2I compared to [ 123 I]FP-CIT (FP-CIT) single-photon emission computed tomography (SPECT) was evaluated. METHODS: Thirty patients with newly onset parkinsonism and 32 healthy controls with both an FE-PE2I and FP-CIT were included in the study. Four patients had normal DAT imaging, of which three did not fulfil the IPS criteria at the clinical reassessment after 2 years. Six raters evaluated the DAT images blinded to the clinical diagnosis, interpreting the image as being 'normal' or 'pathological', and assessed the degree of DAT-reduction in the caudate and putamen. The inter-rater agreement was assessed with intra-class correlation and Cronbach's α . For calculation of sensitivity and specificity, DAT images were defined as correctly classified if categorized as normal or pathological by ≥4/6 raters. RESULTS: The overall agreement in visual evaluation of the FE-PE2I- and FP-CIT images was high for the IPS patients ( α  = 0.960 and 0.898, respectively), but lower in healthy controls (FE-PE2I: α  = 0.693, FP-CIT: α  = 0.657). Visual interpretation gave high sensitivity (both 0.96) but lower specificity (FE-PE2I: 0.86, FP-CIT: 0.63) with an accuracy of 90% for FE-PE2I and 77% for FP-CIT. CONCLUSION: Visual evaluation of FE-PE2I PET imaging demonstrates high reliability and diagnostic accuracy for IPS.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE