RESEARCH / DISCOVERY
← Back to the library

Gait Event Prediction Using Surface Electromyography in Parkinsonian Patients.

Gait Event Prediction Using Surface Electromyography in Parkinsonian Patients.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Berlin, DE · Author affiliation

Uncertainty, Inverse Modeling and Machine Learning Group, Technical University of Berlin, 10587 Berlin, Germany.
Location evidence

Braunschweig, DE · Author affiliation

Mathematical Modelling and Data Analysis Department, Physikalisch-Technische Bundesanstalt Braunschweig und Berlin, 10587 Berlin, Germany.
Location evidence

Würzburg, DE · Author affiliation

Department of Neurology, University Hospital Würzburg and Julius-Maximilians-Universität Würzburg, 97080 Würzburg, Germany.
Location evidence

Centro, IT · Author affiliation

Centro Parkinson, ASST G. Pini-CTO, 20126 Milano, Italy.
Location evidence

Milan, IT · Author affiliation

Centro Parkinson, ASST G. Pini-CTO, 20126 Milano, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Gait disturbances are common manifestations of Parkinson's disease (PD), with unmet therapeutic needs. Inertial measurement units (IMUs) are capable of monitoring gait, but they lack neurophysiological information that may be crucial for studying gait disturbances in these patients. Here, we present a machine learning approach to approximate IMU angular velocity profiles and subsequently gait events using electromyographic (EMG) channels during overground walking in patients with PD. We recorded six parkinsonian patients while they walked for at least three minutes. Patient-agnostic regression models were trained on temporally embedded EMG time series of different combinations of up to five leg muscles bilaterally (i.e., tibialis anterior, soleus, gastrocnemius medialis, gastrocnemius lateralis, and vastus lateralis). Gait events could be detected with high temporal precision (median displacement of <50 ms), low numbers of missed events (<2%), and next to no false-positive event detections (<0.1%). Swing and stance phases could thus be determined with high fidelity (median F1-score of ~0.9). Interestingly, the best performance was obtained using as few as two EMG probes placed on the left and right vastus lateralis. Our results demonstrate the practical utility of the proposed EMG-based system for gait event prediction, which allows the simultaneous acquisition of an electromyographic signal to be performed. This gait analysis approach has the potential to make additional measurement devices such as IMUs and force plates less essential, thereby reducing financial and preparation overheads and discomfort factors in gait studies.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE