RESEARCH / DISCOVERY
← Back to the library

Assessment of different regions of interest-based methods for [99mTc]Tc DAT-SPECT quantification using an anthropomorphic striatal phantom.

Assessment of different regions of interest-based methods for [99mTc]Tc DAT-SPECT quantification using an anthropomorphic striatal phantom.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

São Paulo, BR · Author affiliation

Nuclear Medicine and PET/CT Section, Department of Medical Imaging, Hematology, and Clinical Oncology, University of São Paulo (USP), Ribeirão Preto, Brazil.
Location evidence

Ribeirão Preto, BR · Author affiliation

Nuclear Medicine and PET/CT Section, Department of Medical Imaging, Hematology, and Clinical Oncology, University of São Paulo (USP), Ribeirão Preto, Brazil.
Location evidence

São Carlos, BR · Author affiliation

Interunits Bioengineering Postgraduation Program, São Carlos School of Engineering, University of São Paulo (USP), São Carlos, Brazil.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND AND AIMS: Molecular imaging of the dopamine transporters (DAT) provides valuable information about neurodegenerative diseases, such as Parkinson's. This study assessed the accuracy and precision of DAT-SPECT quantification methods. METHODS: Twenty-three DAT-SPECT images of a striatal phantom were acquired. The specific (caudate and putamen) and the non-specific (background activity) chambers were filled with [99mTc]Tc. Different specific-to-non-specific activity ratios (10, 9, 8, 7, 6, 5, 4, 3 and 2 to 1) and the specific binding ratio (SBR) were calculated. Five methods using ROIs were assessed: (a) Manual ROIs on SPECT images; (b) TwoBox and (c) ThreeBox methods and Volume of Interest (VOI) using structural images; (d) MRI and (e) CT. Accuracy was evaluated by the concordance correlation coefficient (CCC) and precision by Pearson's coefficient and linear regression. RESULTS: The SBR quantified in the specific and striatal chambers resulted in a CCC increase with a decrease in the nominal values. For lower SBR, MRI and CT showed higher CCCs when caudate ([Formula: see text] = 0.89 e [Formula: see text] = 0.84) and putamen ([Formula: see text] = 0.86 e [Formula: see text] = 0.82) were evaluated. For striatal assessments, the TwoBox method was the most accurate ([Formula: see text] = 0.95). High Pearson's coefficients were found in the correlations between all methods. CONCLUSIONS: All five methods showed high precision even when applied to images with different activities. MRI and CT were the most accurate for assessing the caudate or putamen. To assess the striatal chamber and in the absence of structural information, the TwoBox method is advisable.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE