RESEARCH / DISCOVERY
← Back to the library

Design and validation of a multi-task, multi-context protocol for real-world gait simulation.

Design and validation of a multi-task, multi-context protocol for real-world gait simulation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Sheffield, GB · Author affiliation

Department of Mechanical Engineering and Insigneo Institute for in Silico Medicine, The University of Sheffield, Sheffield, UK. kscott3@sheffield.ac.uk.
Location evidence

Sassari, IT · Author affiliation

Department of Biomedical Sciences, University of Sassari, Sassari, Italy.
Location evidence

Newcastle upon Tyne, GB · Author affiliation

Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK.
Location evidence

Tel Aviv, IL · Author affiliation

Center for the Study of Movement, Cognition and Mobility, Neurological Institute, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
Location evidence

Kiel, DE · Author affiliation

Department of Neurology, University Medical Center Schleswig-Holstein Campus Kiel, Kiel, Germany.
Location evidence

Stuttgart, DE · Author affiliation

Robert Bosch Gesellschaft für Medizinische Forschung, Stuttgart, Germany.
Location evidence

Lausanne, CH · Author affiliation

Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Federale de Lausanne, Lausanne, Switzerland.
Location evidence

Turin, IT · Author affiliation

Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.
Location evidence

Bologna, IT · Author affiliation

Department of Electrical, Electronic and Information Engineering «Guglielmo Marconi», University of Bologna, Bologna, Italy.
Location evidence

Erlangen, DE · Author affiliation

Machine Learning and Data Analytics Lab, Department of Artificial Intelligence in Biomedical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Location evidence

Dublin, IE · Author affiliation

Insight Centre for Data Analytics, University College Dublin, Dublin, Ireland.
Location evidence

Basel, CH · Author affiliation

Novartis Institutes of Biomedical Research, Novartis Pharma AG, Basel, Switzerland.
Location evidence

The Hague, NL · Author affiliation

McRoberts BV, The Hague, The Netherlands.
Location evidence

SE · Author affiliation · country only

Digital Health R&D, AstraZeneca, Sweden.
Location evidence

Trondheim, NO · Author affiliation

Department of Neuromedicine and Movement Science, Norwegian University of Science and Technology, Trondheim, Norway.
Location evidence

Aachen, DE · Author affiliation

Grünenthal GmbH, Aachen, Germany.
Location evidence

Barcelona, ES · Author affiliation

Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain.
Location evidence

Madrid, ES · Author affiliation

CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE