RESEARCH / DISCOVERY
← Back to the library

The development and validation of sensitive LC-MS/MS method for quantitative bioanalysis of carmofur in mouse plasma and its application to pharmacokinetic study.

The development and validation of sensitive LC-MS/MS method for quantitative bioanalysis of carmofur in mouse plasma and its application to pharmacokinetic study.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Milwaukee, US · Author affiliation

Department of Chemistry & Biochemistry, University of Wisconsin-Milwaukee, 3210 N Cramer Street, Milwaukee, WI 53211, USA.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

Carmofur is an acid ceramidase inhibitor with superior efficacy in suppressing and killing fatally aggressive glioblastoma cell lines compared to the FDA-approved drug temozolomide. In addition to brain tumors, carmofur also gained attention as a potential lead inhibitor of the main protease (MPRO) of SARS-CoV-2. It is also reported efficacious against numerous other cancers and non-cancerous diseases including acute lung injury, dementia, Parkinson's disease, childhood ependymoma, and Krabbe disease etc. Carmofur also possesses antifungal and antimicrobial properties. Therefore, a sensitive bio-analytical method is needed in order to support further in vivo pharmacological investigation, pre-clinical and clinical studies. Herein, we report a sensitive, and reliable LC-MS/MS method for quantitative bioanalysis of carmofur using mouse plasma. The samples were prepared employing liquid-liquid extraction (LLE) technique using ethyl acetate and 2-propanol (85:15). Chromatographic separation was achieved on an XBridge BEH C18 XP column (100 mm × 3 mm, 2.5 µm) with a runtime of eight minutes. Quantification was performed in multiple reaction monitoring (MRM) mode with precursor to product ion transition of m/z 256.25 → m/z 129.01 for carmofur and m/z 145.53 → m/z 42.00 for 5-chlorouracil (IS) in negative electrospray ionization. Carmofur showed good linearity over the range of 5-1,000 ng.mL-1. The method was validated in terms of specificity, linearity, carry-over, matrix effect, recovery efficiency, accuracy, precision, dilution integrity, and stability. Finally, the method was successfully employed in a pharmacokinetic study in mouse plasma after intraperitoneal administration of the drug solution. To the best of our knowledge, this is the first report of an LC-MS/MS method for carmofur bioanalysis.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE