Video-Based Hand Movement Analysis of Parkinson Patients before and after Medication Using High-Frame-Rate Videos and MediaPipe.
Video-Based Hand Movement Analysis of Parkinson Patients before and after Medication Using High-Frame-Rate Videos and MediaPipe.
Where did the research take place?
The study site has not been established. Author addresses may differ from where the research occurred.
Darmstadt, DE · Author affiliation
KIS*MED (AI Systems in Medicine), Technische Universität Darmstadt, Merckstraße 25, 64283 Darmstadt, GermanyLocation evidence
Aachen, DE · Author affiliation
Department of Neurology, RWTH University Hospital, 52074 Aachen, GermanyLocation evidence
Jülich, DE · Author affiliation
Jülich Aachen Research Alliance (JARA)–JARA-Institute Molecular Neuroscience and Neuroimaging, FZ Jülich and RWTH University, 52428 Jülich, GermanyLocation evidence
Düsseldorf, DE · Author affiliation
Institut für Physikalische Biologie, Düsseldorf, Heinrich-Heine University, 40225 Düsseldorf, GermanyLocation evidence
A plain-language reading has not been prepared for this paper yet.
Original abstract
Tremor is one of the common symptoms of Parkinson's disease (PD). Thanks to the recent evolution of digital technologies, monitoring of PD patients' hand movements employing contactless methods gained momentum. Objective: We aimed to quantitatively assess hand movements in patients suffering from PD using the artificial intelligence (AI)-based hand-tracking technologies of MediaPipe. Method: High-frame-rate videos and accelerometer data were recorded from 11 PD patients, two of whom showed classical Parkinsonian-type tremor. In the OFF-state and 30 Minutes after taking their standard oral medication (ON-state), video recordings were obtained. First, we investigated the frequency and amplitude relationship between the video and accelerometer data. Then, we focused on quantifying the effect of taking standard oral treatments. Results: The data extracted from the video correlated well with the accelerometer-based measurement system. Our video-based approach identified the tremor frequency with a small error rate (mean absolute error 0.229 (±0.174) Hz) and an amplitude with a high correlation. The frequency and amplitude of the hand movement before and after medication in PD patients undergoing medication differ. PD Patients experienced a decrease in the mean value for frequency from 2.012 (±1.385) Hz to 1.526 (±1.007) Hz and in the mean value for amplitude from 8.167 (±15.687) a.u. to 4.033 (±5.671) a.u. Conclusions: Our work achieved an automatic estimation of the movement frequency, including the tremor frequency with a low error rate, and to the best of our knowledge, this is the first paper that presents automated tremor analysis before/after medication in PD, in particular using high-frame-rate video data.