Efficient Entrapment of Alpha-Synuclein Biotinylated Antibody in KCC-1-NH-CS2 and Application for the Sensitive Diagnosis of Parkinson's Using Recognition of Biomarker: An Innovative Electrochemical Label-Free Immunosensor for the Biomedical Analysis of Neurodegenerative Diseases.

Efficient Entrapment of Alpha-Synuclein Biotinylated Antibody in KCC-1-NH-CS2 and Application for the Sensitive Diagnosis of Parkinson's Using Recognition of Biomarker: An Innovative Electrochemical Label-Free Immunosensor for the Biomedical Analysis of Neurodegenerative Diseases.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Nanjing, CN · Author affiliation

Jiangsu Co-Innovation Center for Efficient Processing and Utilization of Forest Resources and International Innovation Center for Forest Chemicals and Materials, Nanjing Forestry University, Nanjing 210037, China.
Location evidence

Tabriz, IR · Author affiliation

Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz 5165665811, Iran.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The early detection of Parkinson's disease (PD) is a critical issue in terms of efficiency. Alpha-synuclein (α-Syn) is a biomarker in PD checks. Alpha-synuclein (α-syn) is the major constituent of Lewy bodies and a pathogenic hallmark of all synucleinopathies, including PDs, dementia with Lewy bodies, and multiple system atrophy. In this study, KCC-1-NH-CS2 was conjugated with biotinylated Ab and entrapped in P(β-CD) polymer cavities. Using this approach, a novel electrochemical label-free immunosensor was designed for the quantification of α-syn in real human samples. For this purpose, the glassy carbon electrode electropolymerized with P(β-CD) biopolymer provided an excellent matrix for entrapping of KCC-1-NH-CS2 loaded with the biotinylated antibody of α-syn. Using the chronoamperometric technique, the proposed immunosensor shows a suitable range of 0.02 to 64 ng/mL for the determination of α-syn. Additionally, a low limit of quantification of the engineered biosensor was obtained at 0.02 ng/mL. The developed immunosensor's adequate stability, sensitivity, and selectivity, together with its ease of manufacture, make it a promising diagnostic technique for further research. This study also will pave the way for further applications of the synergetic effect of β-CD and KCC-1-NH-CS2 for biomedical analysis in the near future.