The study site has not been established. Author addresses may differ from where the research occurred.

Montréal, CA · Author affiliation

Department of Integrated Program in Neuroscience, McGill University, Montreal, Quebec, Canada
Location evidence

Québec, CA · Author affiliation

Department of Integrated Program in Neuroscience, McGill University, Montreal, Quebec, Canada
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) is common in Parkinson disease (PD). Questionnaires can be used as screening tools and have been used as a surrogate definition of OSA in large-scale research. This study aimed to validate the performance of STOP, STOP-BANG, STOP-BAG, STOP-B28, and GOAL and OSA predictors as tools to identify OSA in PD. METHODS: Data were analyzed from a PD cohort study in which OSA was diagnosed using laboratory polysomnography. We calculated sensitivity and specificity of each questionnaire for OSA using different definitions and performed receiver operating characteristics curve analysis. Linear regression was used to assess adjusted associations between questionnaires and outcomes: Montreal Cognitive Assessment, Epworth Sleepiness Scale, and Movement Disorder Society revision of the Unified Parkinson Disease Rating Scale. RESULTS: Questionnaire data were available for 68 PD patients (61.8% male, mean age 64.5 [standard deviation 9.9] years, and Hoehn and Yahr score 2.1 [0.8]). OSA (apnea-hypopnea index ≥ 15 events/h) occurred in 69.4% of participants. STOP-B28 ≥ 2 presented a higher sensitivity for OSA than STOP ≥ 2 (0.76 vs 0.65, respectively) and slightly lower specificity (0.65 vs 0.70, respectively). GOAL ≥ 2 had the highest sensitivity but poor specificity. Loud snoring had sensitivity 0.63 and specificity 0.65. STOP and snoring were significantly associated with Montreal Cognitive Assessment, Epworth Sleepiness Scale, and Movement Disorder Society revision of the Unified Parkinson Disease Rating Scale (total, motor, and nonmotor); STOP-BANG, STOP-BAG, and STOP-B28 showed associations with most outcomes, but the GOAL showed none. CONCLUSIONS: The STOP-B28 followed by STOP and presence of loud snoring alone seem to have the best overall properties to identify PD patients with OSA, whose clinical characteristics differ from the general population with OSA. CITATION: Gomes T, Benedetti A, Lafontaine A-L, Kimoff RJ Robinson A, Kaminska M. Validation of STOP, STOP-BANG, STOP-BAG, STOP-B28, and GOAL screening tools for identification of obstructive sleep apnea in patients with Parkinson disease. J Clin Sleep Med. 2023;19(1):45-54.