RESEARCH / DISCOVERY
← Back to the library

2D MXene/graphene nanocomposite preparation and its electrochemical performance towards the identification of nicotine level in human saliva.

2D MXene/graphene nanocomposite preparation and its electrochemical performance towards the identification of nicotine level in human saliva.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Irvine, US · Author affiliation

Department of Electrical Engineering & Computer Science, 4418 Engineering Hall, The University of California, Irvine, USA; Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603 203, Tamil Nadu, India.
Location evidence

IN · Author affiliation · country only

Department of Electrical Engineering & Computer Science, 4418 Engineering Hall, The University of California, Irvine, USA; Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603 203, Tamil Nadu, India.
Location evidence

Chennai, IN · Author affiliation

Centre for Nano-Biosensors, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical And Technical Sciences, Poonamallee High Road, Velappanchavadi, Chennai 600077, Tamil Nadu, India. Electronic address: ashok.sundramoorthy@gmail.com.
Location evidence

KR · Author affiliation · country only

School of Chemical Engineering, Yeungnam University, Gyeongsan 38541, Republic of Korea.
Location evidence

Riyadh, SA · Author affiliation

Department of Chemistry, College of Science, King Saud University, P. O. Box 2455, Riyadh 11451, Saudi Arabia.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

The quantitative analysis of neurological drugs is critical since the kinetics of body fluids is strongly dependent on the dosage of the drug levels. Thus, the study of neurological medicines is significant because of the major diseases connected to it, for instance, Alzheimer's and Parkinson's diseases. Herein, a 2D hybrid MXene/graphene (MX/Gr) film was synthesized through a top-down approach and utilized to prepare an electrochemical transducer for the electrochemical sensing of nicotine. The X-ray diffraction (XRD), Raman and X-ray photoelectron spectroscopy (XPS) confirmed the successful incorporation of MX with Gr sheets. The high-resolution scanning electron microscopy (HR-SEM) and transmission electron microscopy (TEM) have been used to confirm the formation of MX, graphene sheets and the MX/Gr hybrid film. Furthermore, the MX/Gr hybrid film composite modified glassy carbon electrode (GCE) was prepared to selectively detect the nicotine in phosphate buffer medium (0.1 M PBS, pH~7.4). Under the optimized condition, the MX/Gr/GCE based sensor provided a linear response against nicotine from 1 to 55 µM and 30 nM - 600 nM with the lowest limit of detections (LOD) of 290 nM and 0.28 nM by differential pulse voltammetry (DPV) and amperometry, respectively. This newly developed MX/Gr hybrid film modified electrode displayed a remarkable selectivity, sensitivity, and reproducibility for accurate detection of nicotine. Finally, this new sensor was applied to detect nicotine in human/artificial saliva samples with high accuracy.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE