Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique.

Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Beijing, CN · Author affiliation

Department of Neurology, Xuanwu Hospital of Capital Medical University, Beijing 100053, China.
Location evidence

CN · Author affiliation · country only

Department of Neurosurgery, Affiliated Hospital of Nantong University, Nantong University, Nantong 226001, China.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Frameless robot-assisted deep brain stimulation (DBS) is an innovative technique for leads implantation. This study aimed to evaluate the accuracy and precision of this technique using the Sinovation SR1 robot. METHODS: 35 patients with Parkinson's disease who accepted conventional frame-based DBS surgery (n = 18) and frameless robot-assisted DBS surgery (n = 17) by the same group of neurosurgeons were analyzed. The coordinate of the tip of the intended trajectory was recorded as xi, yi, and zi. The actual position of lead implantation was recorded as xa, ya, and za. The vector error was calculated by the formula of √(xi - xa)2 + (yi - ya)2 + (zi - za)2 to evaluate the accuracy. RESULTS: The vector error was 1.52 ± 0.53 mm (range: 0.20-2.39 mm) in the robot-assisted group and was 1.77 ± 0.67 mm (0.59-2.98 mm) in the frame-based group with no significant difference between two groups (p = 0.1301). In 10.7% (n = 3) frameless robot-assisted implanted leads, the vector error was greater than 2.00 mm with a maximum offset of 2.39 mm, and in 35.5% (n = 11) frame-based implanted leads, the vector error was larger than 2.00 mm with a maximum offset of 2.98 mm. Leads were more posterior than planned trajectories in the robot-assisted group and more medial and posterior in the conventional frame-based group. CONCLUSIONS: Awake frameless robot-assisted DBS surgery was comparable to the conventional frame-based technique in the accuracy and precision for leads implantation.