Hands-feet wireless devices: Test-retest reliability and discriminant validity of motor measures in Parkinson's disease telemonitoring.

Hands-feet wireless devices: Test-retest reliability and discriminant validity of motor measures in Parkinson's disease telemonitoring.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Massa, IT · Author affiliation

Unit of Neurology, Ospedale Apuane, Azienda USL Toscana Nord Ovest, Massa, Italy.
Location evidence

Florence, IT · Author affiliation

Department of Industrial Engineering, University of Florence, Florence, Italy.
Location evidence

Pisa, IT · Author affiliation

Institute of Clinical Physiology, National Research Council (CNR), Pisa, Italy.
Location evidence

Milan, IT · Author affiliation

Department of Neurology - Stroke Unit and Laboratory of Neuroscience, IRCCS Istituto Auxologico Italiano, Milan, Italy.
Location evidence

Bologna, IT · Author affiliation

Department of Biomedical and Neuromotor Sciences University of Bologna, Bologna, Italy.
Location evidence

Palermo, IT · Author affiliation

Department of Biomedicine, Neuroscience and Advanced Diagnostics, University of Palermo, Palermo, Italy.
Location evidence

Pontedera, IT · Author affiliation

The Biorobotics Institute, Scuola Superiore Sant'Anna, Pontedera, Pisa, Italy.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Telemonitoring, a branch of telemedicine, involves the use of technological tools to remotely detect clinical data and evaluate patients. Telemonitoring of patients with Parkinson's disease (PD) should be performed using reliable and discriminant motor measures. Furthermore, the method of data collection and transmission, and the type of subjects suitable for telemonitoring must be well defined. OBJECTIVE: To analyze differences in patients with PD and healthy controls (HC) with the wearable inertial device SensHands-SensFeet (SH-SF), adopting a standardized acquisition mode, to verify if motor measures provided by SH-SF have a high discriminating capacity and high intraclass correlation coefficient (ICC). METHODS: Altogether, 64 patients with mild-to-moderate PD and 50 HC performed 14 standardized motor activities for assessing bradykinesia, postural and resting tremors, and gait parameters. SH-SF inertial devices were used to acquire movements and calculate objective motor measures of movement (total: 75). For each motor task, five or more biomechanical parameters were measured twice. The results were compared between patients with PD and HC. RESULTS: Fifty-eight objective motor measures significantly differed between patients with PD and HC; among these, 32 demonstrated relevant discrimination power (Cohen's d > 0.8). The test-retest reliability was excellent in patients with PD (median ICC = 0.85 right limbs, 0.91 left limbs) and HC (median ICC = 0.78 right limbs, 0.82 left limbs). CONCLUSION: In a supervised environment, the SH-SF device provides motor measures with good results in terms of reliability and discriminant ability. The reliability of SH-SF measurements should be evaluated in an unsupervised home setting in future studies.