RESEARCH / DISCOVERY
← Back to the library

Motor evoked potentials versus Macrostimulation in predicting the postoperative motor threshold in STN Deep brain stimulation.

Motor evoked potentials versus Macrostimulation in predicting the postoperative motor threshold in STN Deep brain stimulation.

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Halifax, CA · Author affiliation

Dalhousie University, Department of Surgery, Division of Neurosurgery, Halifax, Canada. Electronic address: weise@dal.ca.
Location evidence

DE · Author affiliation · country only

Goethe Universität, Department of Neurosurgery, Frankfurt, Germany.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

INTRODUCTION: Accuracy is crucial in Deep Brain Stimulation (DBS). Electrophysiological and image-based techniques are used to avoid suboptimal positioning. Macrostimulation is the gold standard to delineate the therapeutic window intraoperatively. Despite this, electrode revision rates due to malpositioning are as high as 17%. The goal was to compare motor evoked potentials (MEPs) with the gold standard of Macrostimulation. We assessed accuracy and precision as well as the correlation in predicting motor side effects at the initial mapping 4 weeks postoperatively. METHODS: In this prospective study intraoperative MEPs from 94 contacts in 16 patients undergoing STN DBS under local anesthesia were correlated to the postoperative threshold for stimulation-induced motor side effects and compared to intraoperative Macrostimulation. Analysis of accuracy, precision and correlation (Pearson) was performed. RESULTS: MEPs of the upper extremity had a mean percentage error of 25% (SD 38.8%) and correlated significantly with the motor threshold at postoperative mapping (R=0.235). Macrostimulation was less accurate and precise with a mean percentage error of - 68% (SD 78.8%) but had a higher correlation (R=0.388). MEPs rarely (3%) overestimated the threshold by maximally 1 mA. In contrast, Macrostimulation overestimated the threshold by over 1 mA in 69% leading to a false sense of security. CONCLUSION: MEPs are feasible in an awake setting during Deep Brain Stimulation in the STN for PD patients. MEPs of the upper extremity are more accurate and precise predicting the motor threshold and avoid a false sense of security in comparison to the gold standard of Macrostimulation.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.