Original abstract

BACKGROUND: Catheter ablation (CA) in children using fluoroscopy carries risks inherent to ionizing radiation exposure. AIMS: The objective of this study was to demonstrate the feasibility of using low frames rate during ablation in children to maximally decrease radiation dose. METHODS: Hundred sixty eight successive patients<18 years of age undergoing CA performed under a 3.75 frames/second rate were retrospectively included. Demographics, procedural and dosimetry data were analysed. The effective dose (ED) was evaluated in a subgroup of 14 patients. RESULTS: Median age and weight were 15 years and 54kg, 72% had WPW, 10% AV node reentrant tachycardia, 10% ventricular tachycardia (atrial tachycardia, flutter and atrial fibrillation for the other cases). Acute success was achieved in 98.5% without any complication. Median procedure and fluoroscopy duration were 120 and 16minutes. Median Dose Area Product (DAP) and Air Kerma were 2.46Gy.cm2 and 18 mGy respectively (2Gy.cm2 and 15 mGy for WPW ablation). A significant reduction of median DAP was noted over the years for WPW, from 3.1Gy.cm2 in 2011 to 1.4 in 2019. Median estimated ED was 0.19 mSv (0.03 to 1.64), falling into the range of yearly normal natural irradiation or caused by leasure or professional activity. CONCLUSION: Low frame rate fluoroscopy is a highly effective and safe approach in decreasing radiation exposure during CA in children without altering the success rate of the procedure. ED is low, similar to natural/leisure irradiation. This approach can be considered a good alternative to 3D-based procedures in terms of efficiency and radiation issues, at least for WPW ablations.