RESEARCH / DISCOVERY
← Back to the library

Positive QRS complex in limb lead 2 with negative QRS in lead 3 on surface electrocardiogram: A novel predictor for anterior location of right-sided accessory pathways (10-1 o'clock on tricuspid annulus).

Positive QRS complex in limb lead 2 with negative QRS in lead 3 on surface electrocardiogram: A novel predictor for anterior location of right-sided accessory pathways (10-1 o'clock on tricuspid annulus).

Read the original publication

Where did the research take place?

The study site has not been established. Author addresses may differ from where the research occurred.

Kolkata, IN · Author affiliation

Department of Cardiology, Rabindranath Tagore International Institute of Cardiac Sciences (RTIICS), Kolkata, West Bengal, India.
Location evidence

New Delhi, IN · Author affiliation

Department of Cardiology, GB Pant Hospital, New Delhi, India.
Location evidence

Gurugram, IN · Author affiliation

Medanta The Medicity, Gurugram, New Delhi, India.
Location evidence

Explore research worldwide

A plain-language reading has not been prepared for this paper yet.

Original abstract

BACKGROUND: Localization of atrioventricular accessory pathways (AP) from Electrocardiogram (ECG) is crucial for successful ablation. We analyzed the value of limb lead 2 versus 3 QRS vector discordance on surface ECG among right-sided pathways. METHODS: Data from consecutive patients undergoing successful ablation of manifest AP were analyzed. They were categorized into two groups-Gr I: Endocardial ablation from anterior and anterolateral tricuspid annulus (TA, 10-1 o'clock, right anterolateral [RAL]); Gr II: Ablation outside this region (1-10 o'clock of TA). Inferior lead discordance (ILD) was defined as positive QRS complex (monophasic R, Rs) in lead 2 with negative/equiphasic QRS vector in lead 3 (rS, S, RS). Maximally pre-excited ECGs during electrophysiology study were compared for presence of ILD. RESULT: Among total 22 cases (Age 36 ± 18 years, 12 males), ILD was noted in 4/4 cases of Gr I. It was absent among 17/18 cases of right-sided AP in Gr II. The only case in Gr II having ILD was ablated near 8 o'clock (posterolateral). In contrast to the other four cases, aVF was negative, along with lead 3. A close differential was mid-septal AP (MSAP). However, the MSAP had absence of r in V1 and lead 2 having rS/RS complex in contrast to strongly positive QRS in RAL pathways. The sensitivity and specificity of ILD for RAL are 100% and 95%, respectively. The positive, negative predictive value, and accuracy are 80%, 100%, and 95%, respectively. CONCLUSION: Positive QRS complex in lead 2 with negative QRS in lead 3 in maximally pre-excited ECG is often predictive of anterior and anterolateral location among right-sided pathways.

Explore another example or bring your own paper

Pasted text and PDF extraction stay on this computer. The local guide explains terms and surfaces passages; rewriting requires a configured local model. Scanned PDFs need OCR first.

RECORD & PROVENANCE